Siemens EF 83P Series Manuel d'instructions Page 102

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 113
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 101
8-2
8.2 Hydraulic Pressure Setting & Adjustment
Hydraulic pressure adjustment
1) Turn on the machine
power.(Rotating“”position)
2) Loosen the screw nut of main
adjusting valve by using wrench,
then use hexagon wrench to nut
the screw in the nut to get the
required pressure setting.
Set pressure: 35 kg/cm
2
3) Fasten screw nut after setting.
Hydraulic pressure ALARM adjustment
1) According to the above step1
& 2 to adjust pressure to 25
kg/cm
2
.
Set pressure alarm: 25 kg/cm
2
2) Adjust pressure switch until
the buzzer rings, then fix the
switch.
3) According to the hydraulic
pressure adjustment step 2 to
adjust back to 35
kg/cm
2
,
fasten screw nut after setting.
Now the buzzer stopped to
ring.