9.2 Maintenance of the Limit Switch on Z Axis
9.2.1 Select the MPG mode and Z axis which on the control panel.
9.2.2 Adjust the Z axis home position.
Move the Z axis toward to positive direction until the limit
switch touch inside the home dog of the Z axis 4-6mm, as
shown in the below drawing. Now the 0 series diagnosis No.
17 bit 5 (18 series:X1009 bit 1) interchange 1 into 0. If it
doesn’t interchange to 0, please adjust the switch till touch
the home dog and the number is changed to 0.
9.2.3 Move the Z axis continuously and toward to positive
direction when the 0 series diagnosis No. 17 bit 5(18
series:X1009 bit 1) display 0. Then, move again the Z axis
until the 0 series diagnosis No. 17 to 5(18 series:X1009 bit 1)
change 0 into 1. Now the limit switch to away and not touch
the home dog.
9.2.4 Please move Z axis again. When the limit switch touch the
emergency dog, the 0 series diagnosis No. 21 bit 4(18
series:X1008 bit 4) change 1 into 0 and jump to
MDI
mode
on control panel. The screen will display “
NOT READY
message.
9.2.5 Press the EMG. release button. Now, move the Z axis toward
to negative direction and the limit switch go away the
dog. Check the 0 series diagnosis No. 17 bit 5(18
series:X1009 bit 1) and 0 series 21 bit 4(18 series:X1008
bit 1) to display 1.