Parameter table
10-8
© Siemens AG 2010 All Rights Reserved
SICLOCK
®
TC100 Operating Instructions
NTP server
0.16.01
NTP server Operation Min:
Max:
Default:
On
Only when synchronized
On
0.16.02
Multicast[4] Mode Min:
Max:
Default:
Off
60 s with local time
Off
Multicast address Min:
Max:
Default:
0.0.0.0
255.255.255.255
0.0.0.0
NTP client
0.18.01
NTP client Operation Min:
Max:
Default:
Off
On
Off
0.18.02
NTP server list[4] IP address Min:
Max:
Default:
0.0.0.0
255.255.255.255
0.0.0.0
0.18.03
Active server IP address Min:
Max:
Default:
0.0.0.0
255.255.255.255
0.0.0.0
0.18.04
Monitoring Monitoring the server Min:
Max:
Default:
Off
Alarm
Off
Inputs / Input 1
0.20.02
Status Signal Min:
Max:
Default:
No signal
Telegram (disturbed)
No signal
0.20.01
Monitoring Monitor input Min:
Max:
Default:
Off
Alarm
Alarm
Timeout Min:
Max:
Default:
5 mins
1440 mins
30 mins
0.20.03
Framing Baud rate Min:
Max:
Default:
0 Bd
4294967295 Bd
0 Bd
Table 10-1 List of SICLOCK TC100 parameters
Access
1)
/ no.
Parameter Eintry Value range / default