Connection
6-
© Siemens AG 2010 All Rights Reserved
SICLOCK
®
TC100 Operating Instructions
6.3.4 Third-party systems
Third-party systems can also be used for external synchronization of the
SICLOCK TC100 if the following conditions are fulfilled.
Prerequisites
Active radio clock signal with 20mA rated current
Supported signals:
Demodulated DCF77
Serial:
Meinberg format (time-zone dependent),
Meinberg format (time-zone independent),
NMEA (0183/ZDA)
Functional check
The parameter /Inputs/Input 1/Status (0.20.02)
must change to "Meinberg",
"NMEA" or "DCF77" after about three minutes reception.