Product Description of SCALANCE X-400
Operating Instructions for SCALANCE X-400 Industrial Ethernet Switches
36 C79000-G8976-C186-03
Spares
1 C-PLUG (order number: 6GK1 900-0AB00)
7 covers for slots (order number: 6GK5 490-0AA00-0AA2)
- 1 cover for slot 5 (1 Gbps - TP)
- 2 covers for slots 6 and 7
- 1 dummy cover for slot 8
- 3 covers for slots 9 to 11 (100 Mbps - TP)
Terminal set (order number: 6GK5 498-1AA00-0AA0)
- 10 connecting terminals for PS and signaling contact 4-pin
- 10 connecting terminals digital inputs 5-pin
1 location label (order number: 6ES7 912-0AA00-0AA0)
10 sheets of labels (A4) each with 15 labeling strips
(order number: 6GK5 498-0AA00-0AA0)
Slots
The SCALANCE X414-3E basic device consists of a backplane with three perma-
nently installed modules in slots 2, 3 and 4.
Power Module
Digital Inputs
Switch CPU
2 x RJ45
10/100/1000 MBit/s
Twisted Pair
4 x RJ45
10/100/ MBit/s
Twisted Pair
4 x RJ45
10/100/ MBit/s
Twisted Pair
4 x RJ45
10/100/ MBit/s
Twisted Pair
2
3
4
5
6
7
8
9
10
11
Figure 3-3 Basic device without media modules with existing ports