SIMATIC 505PROFIBUS-FMS CommunicationsProcessor (505–CP5434–FMS)User ManualOrder Number: PPX:505–8129–1Text Assembly Number: 2807479–0001Original Edit
viii Contents7.5 FDL Connection Status 7-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the COM5434 Configurator5-36SIMATIC 505 PROFIBUS-FMS CP User Manual5.12 Creating FMS VariablesThe FMS CP module supports up to 100 FMS variables
Using the COM5434 Configurator5-37SIMATIC 505 PROFIBUS-FMS CP User Manual✂File Edit Transfer Options Diagnostics HelpUntitled – COM5434Reference name
Using the COM5434 Configurator5-38SIMATIC 505 PROFIBUS-FMS CP User ManualCreating FMS Variables (continued)PLC Memory When you click on the PLC Memory
Using the COM5434 Configurator5-39SIMATIC 505 PROFIBUS-FMS CP User ManualAccess Groups When you click on the Access Groups field, a buttonappears in
Using the COM5434 Configurator5-40SIMATIC 505 PROFIBUS-FMS CP User ManualCreating FMS Variables (continued)Use Index? Select Yes to specify that the I
Using the COM5434 Configurator5-41SIMATIC 505 PROFIBUS-FMS CP User Manual5.13 Saving and Downloading the ConfigurationYou can save your configuration
Using the COM5434 Configurator5-42SIMATIC 505 PROFIBUS-FMS CP User ManualSaving and Downloading the Configuration (continued)It is always a good pract
Using the COM5434 Configurator5-43SIMATIC 505 PROFIBUS-FMS CP User ManualTo download a configuration to the FMS CP module, follow these steps:1.Make
Configuration Examples6-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 6Configuration Examples6.1 Overview 6-2. . . . . . . . . . . . . . . . . . .
Configuration Examples6-2SIMATIC 505 PROFIBUS-FMS CP User Manual6.1 OverviewThis chapter describes how to define connections and jobs for the FMS CPmo
Contents ixList of Figures1-1 Example of Devices on an FMS Network1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Examples6-3SIMATIC 505 PROFIBUS-FMS CP User ManualFigure 6-2 shows the configuration tasks you must complete to configure theFMS CP mod
Configuration Examples6-4SIMATIC 505 PROFIBUS-FMS CP User Manual6.2 Example of an FMS Read JobFigure 6-3 shows the flow of data during an FMS Read job
Configuration Examples6-5SIMATIC 505 PROFIBUS-FMS CP User ManualThe first step in the process is to create the configuration file. Click on thetop ic
Configuration Examples6-6SIMATIC 505 PROFIBUS-FMS CP User ManualExample of an FMS Read Job (continued)Next, you must define the Module Local Configura
Configuration Examples6-7SIMATIC 505 PROFIBUS-FMS CP User ManualContinue configuring the FMS Read job by defining the FMS connection forthe FMS CP mo
Configuration Examples6-8SIMATIC 505 PROFIBUS-FMS CP User ManualExample of an FMS Read Job (continued)Once you have defined the Module Local Configura
Configuration Examples6-9SIMATIC 505 PROFIBUS-FMS CP User ManualSave your file to disk before attempting to transfer the file to the FMS CPmodule. Fo
Configuration Examples6-10SIMATIC 505 PROFIBUS-FMS CP User ManualExample of an FMS Read Job (continued)After you configure the FMS Read job for Statio
Configuration Examples6-11SIMATIC 505 PROFIBUS-FMS CP User ManualContinue configuring the FMS Read job by defining an FMS variable for theFMS CP modu
Configuration Examples6-12SIMATIC 505 PROFIBUS-FMS CP User ManualExample of an FMS Read Job (continued)Save your file to disk before attempting to tra
x ContentsList of Figures (continued)5-8 Module Local Configuration5-13. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Examples6-13SIMATIC 505 PROFIBUS-FMS CP User ManualC99BITP1A: WX1N=2C99 C100C99BITP1 And BITP2 verify that no previous jobs are in prog
Configuration Examples6-14SIMATIC 505 PROFIBUS-FMS CP User Manual6.3 Example of a Send-Receive JobFigure 6-11 shows the flow of data during Send-Recei
Configuration Examples6-15SIMATIC 505 PROFIBUS-FMS CP User ManualThe first step in the process is to create the configuration file.1.Select the menu
Configuration Examples6-16SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Send-Receive Job (continued)Next, you must define the Module Local Confi
Configuration Examples6-17SIMATIC 505 PROFIBUS-FMS CP User ManualContinue configuring the Send job for Station 1 by defining the FDLconnection for th
Configuration Examples6-18SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Send-Receive Job (continued)Once you have defined the Module Local Confi
Configuration Examples6-19SIMATIC 505 PROFIBUS-FMS CP User ManualYou should save your file to disk before attempting to transfer the file to theFMS C
Configuration Examples6-20SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Send-Receive Job (continued)After you create a Send job for Station 1, y
Configuration Examples6-21SIMATIC 505 PROFIBUS-FMS CP User ManualOnce you have defined the Module Local Configuration and the FDLconnection, you can
Configuration Examples6-22SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Send-Receive Job (continued)After you successfully load the configuratio
Contents xi6-16 Send Relay Ladder Logic for Station 16-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-17
Configuration Examples6-23SIMATIC 505 PROFIBUS-FMS CP User ManualC98XnMOVW1A: 1B:V300N=1Enabling Rung (User Logic)C43C30C98A: WY5N=1C101BITP3A: WX1N=
Configuration Examples6-24SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Send-Receive Job (continued)The Relay Ladder Logic example in Figure 6-1
Configuration Examples6-25SIMATIC 505 PROFIBUS-FMS CP User ManualC49MOVW1A: 1B:V302N=3C33 C40C49C50BITP1A: WX3N=3BITP2A: WY7N=3C31C45C49C37C38C50 C31
Configuration Examples6-26SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Send-Receive Job (continued)Figure 6-18 shows the sequence of events for
Configuration Examples6-27SIMATIC 505 PROFIBUS-FMS CP User ManualFigure 6-19 shows the sequence of events for an unsuccessful FDLtransaction.WY5.3WX1
Configuration Examples6-28SIMATIC 505 PROFIBUS-FMS CP User Manual6.4 Example of a Peerlink II Transmit and Receive ServiceFigure 6-20 shows Transmit a
Configuration Examples6-29SIMATIC 505 PROFIBUS-FMS CP User ManualThe first step in the process is to create the configuration file for Station 1.1.Se
Configuration Examples6-30SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Peerlink II Transmit and Receive Service (continued)Next, you must defin
Configuration Examples6-31SIMATIC 505 PROFIBUS-FMS CP User ManualOnce you have defined the Module Local Configuration, you can configurethe peer tran
Configuration Examples6-32SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Peerlink II Transmit and Receive Service (continued)3. Click on the New
xii ContentsList of Tables1-1 PROFIBUS Physical Parameters1-6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration Examples6-33SIMATIC 505 PROFIBUS-FMS CP User ManualContinue by configuring the parameters for a Receive service.1.Click on the New Item
Configuration Examples6-34SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Peerlink II Transmit and Receive Service (continued)The second step in t
Configuration Examples6-35SIMATIC 505 PROFIBUS-FMS CP User ManualNext, you must define the Module Local Configuration of the FMS CPmodule for Station
Configuration Examples6-36SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Peerlink II Transmit and Receive Service (continued)Once you have define
Configuration Examples6-37SIMATIC 505 PROFIBUS-FMS CP User Manual3. Click on the New Item button on the toolbar.4.Complete the fields listed below (a
Configuration Examples6-38SIMATIC 505 PROFIBUS-FMS CP User ManualExample of a Peerlink II Transmit and Receive Service (continued)Continue by configur
Configuration Examples6-39SIMATIC 505 PROFIBUS-FMS CP User ManualNext, save your file to disk before attempting to transfer the file to theFMS CP mod
Diagnostics7-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 7Diagnostics7.1 CP Status7-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Diagnostics7-2SIMATIC 505 PROFIBUS-FMS CP User Manual7.1 CP StatusThe Read CP Status dialog provides useful information on the operatingstatus of the
Diagnostics7-3SIMATIC 505 PROFIBUS-FMS CP User Manual7.2 Active StationsThe List of Active Stations dialog lists all stations on the bus and thecurre
PrefacexiiiSIMATIC 505 PROFIBUS-FMS CP User ManualPrefaceThis manual describes the SIMATIC 505 PROFIBUS-FMS CommunicationsProcessor module for the Se
Diagnostics7-4SIMATIC 505 PROFIBUS-FMS CP User Manual7.3 PROFIBUS StatisticsThe PROFIBUS Statistics dialog provides statistical information about thes
Diagnostics7-5SIMATIC 505 PROFIBUS-FMS CP User Manual7.4 FMS Connection StatusThe List of FMS Connections dialog lists the existing configured FMScon
Diagnostics7-6SIMATIC 505 PROFIBUS-FMS CP User Manual7.5 FDL Connection StatusThe List of FDL Connections dialog lists the existing configured FDLconn
Diagnostics7-7SIMATIC 505 PROFIBUS-FMS CP User Manual7.6 Job StatusThe List of FMS/Send-Receive Jobs dialog lists the existing FMS jobs andSend-Recei
Diagnostics7-8SIMATIC 505 PROFIBUS-FMS CP User Manual7.7 Peer Block StatusThe List of Configured Peer Blocks dialog lists the existing configured Peer
Reference DataA-1SIMATIC 505 PROFIBUS-FMS CP User ManualAppendix AReference DataA.1 Data Element ListA-2. . . . . . . . . . . . . . . . . . . . . . .
Reference DataA-2SIMATIC 505 PROFIBUS-FMS CP User ManualA.1 Data Element ListTable A-1 shows the allowed data types (elements) for local or remoteSIMA
Reference DataA-3SIMATIC 505 PROFIBUS-FMS CP User ManualTable A-1Data Element List (continued)Data Element DescriptionNotes NamePLCTTAccessPLCReprese
Reference DataA-4SIMATIC 505 PROFIBUS-FMS CP User ManualData Element List (continued)Table A-1Data Element List (continued)Data Element DescriptionNot
Reference DataA-5SIMATIC 505 PROFIBUS-FMS CP User ManualTable A-1Data Element List (continued)Data Element DescriptionNotes NamePLCTTAccessPLCReprese
PrefacexivSIMATIC 505 PROFIBUS-FMS CP User ManualThe following conventions are used in this manual:•“Click” means to place the mouse cursor on an obje
Reference DataA-6SIMATIC 505 PROFIBUS-FMS CP User ManualA.2 Data Access between SIMATIC S7 and SIMATIC 505 SystemsVariables in the SIMATIC 505 system
Reference DataA-7SIMATIC 505 PROFIBUS-FMS CP User ManualTo derive the SIMATIC S7 address for a SIMATIC 505 variable, use thefollowing steps:1.Subtrac
Reference DataA-8SIMATIC 505 PROFIBUS-FMS CP User ManualA.3 Mapping of FMS Variables onto 505 MemoryFigure A-2 shows examples of how simple variables
Reference DataA-9SIMATIC 505 PROFIBUS-FMS CP User Manual12345678910111213141516XTime Difference11234567891011121314151605Visible String51A Visible St
Reference DataA-10SIMATIC 505 PROFIBUS-FMS CP User ManualMapping of FMS Variables onto 505 Memory (continued)Figure A-3 shows how variable arrays are
Reference DataA-11SIMATIC 505 PROFIBUS-FMS CP User ManualFigure A-4 shows how an example structure of data types is mapped inSIMATIC 505 memory.STRUC
Reference DataA-12SIMATIC 505 PROFIBUS-FMS CP User ManualMapping of FMS Variables onto 505 Memory (continued)The FMS Status request function allows st
Reference DataA-13SIMATIC 505 PROFIBUS-FMS CP User ManualThe FMS Identify request function allows the following information to beobtained from the pa
Reference DataA-14SIMATIC 505 PROFIBUS-FMS CP User ManualA.4 Protocol Implementation Conformance Statements (PICS)The Protocol Implementation Conforma
Reference DataA-15SIMATIC 505 PROFIBUS-FMS CP User ManualTable A-6PICS Part 3: FMS Parameters and OptionsFMS Parameters and Options DetailAddressing
Overview1-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 1Overview1.1 The SIMATIC 505 PROFIBUS-FMS Communications Processor Module1-2. . . . . . . .
Reference DataA-16SIMATIC 505 PROFIBUS-FMS CP User ManualA.5 FMS Connection Types and VariablesWhen configuring FMS connections, you must specify the
Reference DataA-17SIMATIC 505 PROFIBUS-FMS CP User ManualYou can enable and disable read or write access to each variable in yourconfiguration. The A
Reference DataA-18SIMATIC 505 PROFIBUS-FMS CP User ManualA.6 Local LSAP AssignmentsTable A-10 lists the available LSAP assignment numbers and anyrestr
TroubleshootingB-1SIMATIC 505 PROFIBUS-FMS CP User ManualAppendix BTroubleshootingB.1 Using the RESET Button B-2. . . . . . . . . . . . . . . . . . .
TroubleshootingB-2SIMATIC 505 PROFIBUS-FMS CP User ManualB.1 Using the RESET ButtonFirst attempt to reset the module using the COM5434 Configuratorsof
TroubleshootingB-3SIMATIC 505 PROFIBUS-FMS CP User ManualB.2 Job Status CodesTable B-1 lists the status codes and their meanings for FMS orSend-Recei
TroubleshootingB-4SIMATIC 505 PROFIBUS-FMS CP User ManualJob Status Codes (continued)Table B-2Local FMS Job Status Codes (continued)Error Description0
TroubleshootingB-5SIMATIC 505 PROFIBUS-FMS CP User ManualTable B-3 lists FMS job error codes signaled by the communication partner.Table B-3Errors Si
TroubleshootingB-6SIMATIC 505 PROFIBUS-FMS CP User ManualJob Status Codes (continued)Table B-4 lists the error codes and their meanings for Send-Recei
TroubleshootingB-7SIMATIC 505 PROFIBUS-FMS CP User ManualB.3 CP-to-Controller Status CodesTable B-5CP-to-Attached Controller Error Codes for FMS and
Overview1-2SIMATIC 505 PROFIBUS-FMS CP User Manual1.1 The SIMATIC 505 PROFIBUS-FMS Communications Processor ModuleThe SIMATIC 505 PROFIBUS-FMS Communi
SpecificationsC-1SIMATIC 505 PROFIBUS-FMS CP User ManualAppendix CSpecificationsTable C-1Communication CapacitiesCommunication Type Maximum Number or
SpecificationsC-2SIMATIC 505 PROFIBUS-FMS CP User Manual Table C-3SpecificationsOperating temperature(Based on the immediate surroundingair at the dev
Index-1IndexAAccess groups, 5-22, 5-39Access rights, 5-38Active stations status, 7-3Addressing, network, 4-7Agency approvals, xiv, C-2Arraysexamples,
Index-2 FFDL connection, status, 7-6FDL servicesconfiguring Send-Receive jobs, 5-30–5-32defining connections, 5-23–5-25definition, 4-2Featuresbezel, 1
Index-3NNetwork addressing, 4-7Networking overview, 1-6–1-10OObject dictionarydefinition, 4-8selecting, 5-22OSI 7 layer model, 1-7PPassworddefinition
Index-4 Send-Receive, configuring jobs, 5-30–5-32Send-Receive job example, 6-14–6-27Send-Receive services, overview, 4-11Serial port setup, 5-3–5-5SIM
Customer ResponseWe would like to know what you think about our user manuals so that we can serve you better.How would you rate the quality of our man
BUSINESS REPLY MAILFIRST CLASSPERMIT NO.3JOHNSON CITY, TNFOLDFOLDPOSTAGE WILL BE PAID BY ADDRESSEENO POSTAGENECESSARYIF MAILEDIN THEUNITED STATESATTN
Overview1-3SIMATIC 505 PROFIBUS-FMS CP User ManualThe SIMATIC 505 PROFIBUS-FMS Communications Processor module iscompatible with all SIMATIC 545, 555
!DANGERDANGER indicates an imminently hazardous situation that, if not avoided, willresult in death or serious injury.DANGER is limited to the most ex
Overview1-4SIMATIC 505 PROFIBUS-FMS CP User Manual1.2 Hardware OverviewAs shown in Figure 1-2, the bezel of the FMS CP module has four statusLEDs, a r
Overview1-5SIMATIC 505 PROFIBUS-FMS CP User ManualBelow the LEDs is a recessed RUN/STOP toggle switch. The switch can bemoved from one position to an
Overview1-6SIMATIC 505 PROFIBUS-FMS CP User Manual1.3 Network OverviewThe Process Field Bus (PROFIBUS) standard (EN 50 170, Volume 2,PROFIBUS) defines
Overview1-7SIMATIC 505 PROFIBUS-FMS CP User ManualThe Open Systems Interconnection (OSI) 7 Layer Model defines levels ofcommunication from the physic
Overview1-8SIMATIC 505 PROFIBUS-FMS CP User ManualNetwork Overview (continued)PROFIBUS allows for multiple masters on a single network, where eachmast
Overview1-9SIMATIC 505 PROFIBUS-FMS CP User ManualCommunication on the PROFIBUS network can be described from both thephysical and the logical point
Overview1-10SIMATIC 505 PROFIBUS-FMS CP User ManualNetwork Overview (continued)Figure 1-7 shows how three stations on a network are configured tocommu
Installing the Module2-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 2Installing the Module2.1 Overview of Installation2-2. . . . . . . . . . . . .
Installing the Module2-2SIMATIC 505 PROFIBUS-FMS CP User Manual2.1 Overview of InstallationFollow the flow of tasks shown in Figure 2-1 when installin
Installing the Module2-3SIMATIC 505 PROFIBUS-FMS CP User Manual!CAUTIONElectronic equipment is sensitive to, and can be damaged by, electrostaticdisc
MANUAL PUBLICATION HISTORYSIMATIC 505 PROFIBUS-FMS Communications Processor User ManualOrder Manual Number: PPX:505–8129–1Refer to this history in a
Installing the Module2-4SIMATIC 505 PROFIBUS-FMS CP User Manual2.2 Setting the Baud Rate for the RS-232 PortA header labeled E1 is located on the modu
Installing the Module2-5SIMATIC 505 PROFIBUS-FMS CP User Manual2.3 Inserting the FMS CP Module!WARNINGElectrical shock hazard is possible if you do n
Installing the Module2-6SIMATIC 505 PROFIBUS-FMS CP User Manual2.4 Connecting a Programming Device to the FMS CP ModuleThe RS-232 port is the interfac
Installing the Module2-7SIMATIC 505 PROFIBUS-FMS CP User Manual2.5 Connecting the FMS CP Module to the NetworkThe PROFIBUS-FMS port is the interface
Installing the Module2-8SIMATIC 505 PROFIBUS-FMS CP User Manual2.6 Powering Up the BaseRefer to the system manual for your programmable logic controll
Installing the Module2-9SIMATIC 505 PROFIBUS-FMS CP User ManualThe operating modes of the FMS CP module, which are indicated by theLED status, are de
Installing the Module2-10SIMATIC 505 PROFIBUS-FMS CP User Manual2.7 Configuring the I/O Address in the Programmable Logic ControllerAfter installing t
Installing the Module2-11SIMATIC 505 PROFIBUS-FMS CP User ManualNOTE: Because discretes and words do not share the same image registeraddresses, the
Installing the Module2-12SIMATIC 505 PROFIBUS-FMS CP User Manual2.8 PROFIBUS Network Card and Software PackagesYou must install one of the PROFIBUS ca
Connecting the Network3-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 3Connecting the Network3.1 Cables and Connectors3-2. . . . . . . . . . . . .
LIST OF EFFECTIVE PAGESPages Description Pages DescriptionCover/Copyright OriginalHistory/Effective PagesOriginaliii — xivOriginal1-1 — 1-10 Original
Connecting the Network3-2SIMATIC 505 PROFIBUS-FMS CP User Manual3.1 Cables and ConnectorsThis section describes products available from Siemens that a
Connecting the Network3-3SIMATIC 505 PROFIBUS-FMS CP User ManualStandard cable connectors that conform to the PROFIBUS requirements areshown in Figur
Connecting the Network3-4SIMATIC 505 PROFIBUS-FMS CP User ManualCables and Connectors (continued)A PROFIBUS repeater available from Siemens is shown i
Connecting the Network3-5SIMATIC 505 PROFIBUS-FMS CP User Manual3.2 Cable RoutingFollow these suggestions when planning your cable routing.•Allow for
Connecting the Network3-6SIMATIC 505 PROFIBUS-FMS CP User ManualCable Routing (continued)For in-ceiling routing, cables are usually supported in troug
Connecting the Network3-7SIMATIC 505 PROFIBUS-FMS CP User Manual3.3 Installing PROFIBUS CablesThe PROFIBUS-FMS port provides communication over shiel
Connecting the Network3-8SIMATIC 505 PROFIBUS-FMS CP User ManualInstalling PROFIBUS Cables (continued)Table 3-1 lists the PROFIBUS EN 50 170 cable lin
Connecting the Network3-9SIMATIC 505 PROFIBUS-FMS CP User ManualThe rules for proper PROFIBUS installation follow:•Create a daisy-chain arrangement,
Connecting the Network3-10SIMATIC 505 PROFIBUS-FMS CP User ManualInstalling PROFIBUS Cables (continued)The device at each extreme end of a PROFIBUS ca
Connecting the Network3-11SIMATIC 505 PROFIBUS-FMS CP User ManualFigure 3-7 shows the schematic for PROFIBUS connectors designed tohandle all baud ra
Contents iiiContentsPrefaceChapter 1 Overview1.1 The SIMATIC 505 PROFIBUS-FMS Communications Processor Module1-2. . . . . . . . . . . . . . . Feature
Connecting the Network3-12SIMATIC 505 PROFIBUS-FMS CP User ManualInstalling PROFIBUS Cables (continued)The following procedure describes how to attach
Connecting the Network3-13SIMATIC 505 PROFIBUS-FMS CP User Manual5. Remove 0.25 inches (6 mm) of insulation at the wire ends.6.Insert the signal wire
Communication Services4-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 4Communication Services4.1 Overview 4-2. . . . . . . . . . . . . . . . . . .
Communication Services4-2SIMATIC 505 PROFIBUS-FMS CP User Manual4.1 OverviewThe FMS CP module supports the following types of communicationservices:•F
Communication Services4-3SIMATIC 505 PROFIBUS-FMS CP User ManualConnections are the logical links between stations on the network. Youdefine connecti
Communication Services4-4SIMATIC 505 PROFIBUS-FMS CP User ManualOverview (continued)The FMS CP module is registered in the I/O memory map of its contr
Communication Services4-5SIMATIC 505 PROFIBUS-FMS CP User ManualThese bits are used to synchronize (handshake) communication between theuser program
Communication Services4-6SIMATIC 505 PROFIBUS-FMS CP User ManualOverview (continued)4. The programmable logic controller recognizes the WX bit transit
Communication Services4-7SIMATIC 505 PROFIBUS-FMS CP User Manual4.2 Addressing on Your NetworkPROFIBUS networks use a system of multiplexed addressin
Communication Services4-8SIMATIC 505 PROFIBUS-FMS CP User Manual4.3 FMS ServicesBefore you configure an FMS communication job, you must first define a
iv Contents2.6 Powering Up the Base2-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Communication Services4-9SIMATIC 505 PROFIBUS-FMS CP User ManualFigure 4-4 shows the data flow of each FMS communication job. Each FMScommunication j
Communication Services4-10SIMATIC 505 PROFIBUS-FMS CP User ManualFMS Services (continued)When you define an FMS connection, you must specify access ri
Communication Services4-11SIMATIC 505 PROFIBUS-FMS CP User Manual4.4 Send-Receive ServicesBefore you configure a Send-Receive job, you must first def
Communication Services4-12SIMATIC 505 PROFIBUS-FMS CP User Manual4.5 Peerlink II ServicesPeerlink II is an unacknowledged broadcast service that allow
Communication Services4-13SIMATIC 505 PROFIBUS-FMS CP User Manual4.6 S7 ServicesS7 services allow S7 devices to read and write data in the 505 CPU me
Using the COM5434 Configurator5-1SIMATIC 505 PROFIBUS-FMS CP User ManualChapter 5Using the COM5434 Configurator5.1 Installing the Software for the FM
Using the COM5434 Configurator5-2SIMATIC 505 PROFIBUS-FMS CP User Manual5.1 Installing the Software for the FMS CP ModuleThe COM5434 Configurator soft
Using the COM5434 Configurator5-3SIMATIC 505 PROFIBUS-FMS CP User ManualIf you have successfully installed the COM5434 Configurator software, youcan
Using the COM5434 Configurator5-4SIMATIC 505 PROFIBUS-FMS CP User ManualInstalling the Software for the FMS CP Module (continued)3. Select the port nu
Using the COM5434 Configurator5-5SIMATIC 505 PROFIBUS-FMS CP User ManualUse the following procedure to configure your PC to communicate on aPROFIBUS
Contents v4.3 FMS Services4-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the COM5434 Configurator5-6SIMATIC 505 PROFIBUS-FMS CP User Manual5.2 Features and Functions of the COM5434 Configurator SoftwareTo use all of t
Using the COM5434 Configurator5-7SIMATIC 505 PROFIBUS-FMS CP User ManualThe main features of the COM5434 Configurator screen (shown inFigure 5-5) are
Using the COM5434 Configurator5-8SIMATIC 505 PROFIBUS-FMS CP User ManualFeatures and Functions of the COM5434 Configurator Software (continued)Table 5
Using the COM5434 Configurator5-9SIMATIC 505 PROFIBUS-FMS CP User ManualTable 5-1Menu Commands (continued)Menu CommandsDescriptionOptions✔ Validate P
Using the COM5434 Configurator5-10SIMATIC 505 PROFIBUS-FMS CP User ManualFeatures and Functions of the COM5434 Configurator Software (continued)The to
Using the COM5434 Configurator5-11SIMATIC 505 PROFIBUS-FMS CP User ManualWhen your mouse cursor is on an item in the configuration tree, you canclick
Using the COM5434 Configurator5-12SIMATIC 505 PROFIBUS-FMS CP User Manual5.3 Describing the Configuration File✂File Edit Transfer Options Diagnostics
Using the COM5434 Configurator5-13SIMATIC 505 PROFIBUS-FMS CP User Manual5.4 Defining the Module Local ConfigurationThe module local configuration, s
Using the COM5434 Configurator5-14SIMATIC 505 PROFIBUS-FMS CP User ManualDefining the Module Local Configuration (continued)Highest Station Address Us
Using the COM5434 Configurator5-15SIMATIC 505 PROFIBUS-FMS CP User ManualNOTE: If you customize the Bus Parameter Profile by selecting Custom inthe
vi Contents5.7 Defining FDL Connections5-23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Using the COM5434 Configurator5-16SIMATIC 505 PROFIBUS-FMS CP User Manual5.5 Defining Peerlink II ServicesThe FMS CP module supports a maximum of 32 P
Using the COM5434 Configurator5-17SIMATIC 505 PROFIBUS-FMS CP User Manual✂File Edit Transfer Options Diagnostics HelpUntitled – COM5434Configured cyc
Using the COM5434 Configurator5-18SIMATIC 505 PROFIBUS-FMS CP User ManualDefining Peerlink II Services (continued)Peer Block Type Select either Receiv
Using the COM5434 Configurator5-19SIMATIC 505 PROFIBUS-FMS CP User Manual5.6 Defining FMS ConnectionsThe FMS CP module supports up to 32 FMS connecti
Using the COM5434 Configurator5-20SIMATIC 505 PROFIBUS-FMS CP User ManualDefining FMS Connections (continued)✂File Edit Transfer Options Diagnostics H
Using the COM5434 Configurator5-21SIMATIC 505 PROFIBUS-FMS CP User ManualRemote Station Address Enter the PROFIBUS network address usedby the remote
Using the COM5434 Configurator5-22SIMATIC 505 PROFIBUS-FMS CP User ManualDefining FMS Connections (continued)Access Groups When you click on the Acces
Using the COM5434 Configurator5-23SIMATIC 505 PROFIBUS-FMS CP User Manual5.7 Defining FDL ConnectionsThe FMS CP module supports up to 32 FDL connecti
Using the COM5434 Configurator5-24SIMATIC 505 PROFIBUS-FMS CP User ManualDefining FDL Connections (continued)✂File Edit Transfer Options Diagnostics H
Using the COM5434 Configurator5-25SIMATIC 505 PROFIBUS-FMS CP User ManualLocal LSAP Enter a numeric value for the local Link Service AccessPoint for
Contents vii6.3 Example of a Send-Receive Job6-14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Co
Using the COM5434 Configurator5-26SIMATIC 505 PROFIBUS-FMS CP User Manual5.8 Overview of Communication JobsThe FMS CP module supports a maximum of 48
Using the COM5434 Configurator5-27SIMATIC 505 PROFIBUS-FMS CP User Manual5.9 Configuring FMS JobsBefore you can configure an FMS job, you must have d
Using the COM5434 Configurator5-28SIMATIC 505 PROFIBUS-FMS CP User ManualConfiguring FMS Jobs (continued)✂File Edit Transfer Options Diagnostics HelpU
Using the COM5434 Configurator5-29SIMATIC 505 PROFIBUS-FMS CP User ManualJob Type Select Read, Write, Information Report, Status, or Identifyfrom the
Using the COM5434 Configurator5-30SIMATIC 505 PROFIBUS-FMS CP User Manual5.10 Configuring Send-Receive JobsBefore you can configure a Send-Receive job
Using the COM5434 Configurator5-31SIMATIC 505 PROFIBUS-FMS CP User Manual✂File Edit Transfer Options Diagnostics HelpUntitled – COM5434Reference name
Using the COM5434 Configurator5-32SIMATIC 505 PROFIBUS-FMS CP User ManualConfiguring Send-Receive Jobs (continued)Job Type Select Send or Receive from
Using the COM5434 Configurator5-33SIMATIC 505 PROFIBUS-FMS CP User Manual5.11 Creating FMS Data TypesThe FMS CP module supports up to 85 FMS data typ
Using the COM5434 Configurator5-34SIMATIC 505 PROFIBUS-FMS CP User ManualCreating FMS Data Types (continued)✂File Edit Transfer Options Diagnostics He
Using the COM5434 Configurator5-35SIMATIC 505 PROFIBUS-FMS CP User ManualDefinition When you click on the Definition field, a button appears.Click on
Commentaires sur ces manuels