Installation 10 Siemens Building Technologies Fire Safety & Security Products 08.2007 6 Installation 6.1 SISTORE MX NVS installieren Vorau
Installation 11 Siemens Building Technologies Fire Safety & Security Products 08.2007 5. Klicken Sie auf die Schaltfläche Weiter. Î Folge
Installation 12 Siemens Building Technologies Fire Safety & Security Products 08.2007 10. Geben Sie hier den Name des Programmordners ein
Installation 13 Siemens Building Technologies Fire Safety & Security Products 08.2007 14. Klicken Sie auf die Schaltfläche Fertig stellen.
Installation 14 Siemens Building Technologies Fire Safety & Security Products 08.2007 6.2 Hardware-Treiber nachinstallieren Voraussetzung:
Installation 15 Siemens Building Technologies Fire Safety & Security Products 08.2007 Hardware-Treiber Funktion CKA4810/CKA4820 Ansteuer
Installation 16 Siemens Building Technologies Fire Safety & Security Products 08.2007 6.3 RemoteView auf Client-PC installieren Voraussetz
Installation 17 Siemens Building Technologies Fire Safety & Security Products 08.2007 5. Klicken Sie auf die Schaltfläche Weiter. Î Folge
Installation 18 Siemens Building Technologies Fire Safety & Security Products 08.2007 Î Folgendes Dialogfenster wird geöffnet: Abb. 5 Prog
Installation 19 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 6 Installation abgeschlossen 13. Klicken Sie
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. © 2007
Installation 20 Siemens Building Technologies Fire Safety & Security Products 08.2007 6.4 SISTORE MX NVS entfernen 1. Starten Sie die Dat
Konfiguration 21 Siemens Building Technologies Fire Safety & Security Products 08.2007 7 Konfiguration 7.1 Software aufrufen 1. Doppelkli
Konfiguration 22 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.2 In das System einloggen 1. Wählen Sie aus dem
Konfiguration 23 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.4 Passwort ändern Sie haben zwei Möglichkeiten da
Konfiguration 24 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.5 Sprachversion ändern 1. Wählen Sie aus dem Menü
Konfiguration 25 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.6 Sprachversion unter Windows XP ändern 1. Wähl
Konfiguration 26 Siemens Building Technologies Fire Safety & Security Products 08.2007 Î Folgendes Dialogfenster wird geöffnet: 6. Klicken
Konfiguration 27 Siemens Building Technologies Fire Safety & Security Products 08.2007 Î Das Dialogfenster Regions- und Sprachoptionen öffn
Konfiguration 28 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.7 Datum und Uhrzeit auf deutsches Format stellen
Konfiguration 29 Siemens Building Technologies Fire Safety & Security Products 08.2007 7. Wechseln Sie das Register Datum. Î Folgendes Di
3 Siemens Building Technologies Fire Safety & Security Products 08.2007 Inhalt 1 Sicherheit...
Konfiguration 30 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.8 Auflösung und Dateiformat Die von SISTORE MX NVS
Konfiguration 31 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.9 Zeitzone und Uhrzeit des PCs einstellen Stelle
Konfiguration 32 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.10 Zeit des Client PCs von NTP-Server holen Ein N
Konfiguration 33 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.11 Weitere Informationen Ausführliche Information
Software aktualisieren 34 Siemens Building Technologies Fire Safety & Security Products 08.2007 8 Software aktualisieren Sollte es zu einem
Inbetriebnahme 35 Siemens Building Technologies Fire Safety & Security Products 08.2007 10 Inbetriebnahme 10.1 Beispiele für Systemaufbau
Inbetriebnahme 36 Siemens Building Technologies Fire Safety & Security Products 08.2007 SISTORE MX NVS unterstützt folgende Netzwerkkameras:
Inbetriebnahme 37 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.2 SISTORE MX NVS – IP-Kamera – CKA4810 / 20 A
Inbetriebnahme 38 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.3 SISTORE MX NVS – SISTORE RemoteView – CKA4810
Inbetriebnahme 39 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.4 SISTORE MX NVS – SISTORE MX NVS RemoteView –
Sicherheit 4 Siemens Building Technologies Fire Safety & Security Products 08.2007 10 Inbetriebnahme ...
Inbetriebnahme 40 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.5 SISTORE MX NVS – MX Multi Channel Box RCI 0601
USB Ein-/Ausgangsmodule 41 Siemens Building Technologies Fire Safety & Security Products 08.2007 11 USB Ein-/Ausgangsmodule Die USB Ein-/A
USB Ein-/Ausgangsmodule 42 Siemens Building Technologies Fire Safety & Security Products 08.2007 11.1 Technische Daten USB Ein-/Ausgangsmod
USB Ein-/Ausgangsmodule 43 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 16 USB Eingangsmodul 1 Module Ad
USB Ein-/Ausgangsmodule 44 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 18 USB Ausgangsmodul 1 Relay Out
USB Ein-/Ausgangsmodule 45 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 20 USB Ein- und Ausgangsmodul 1, 2
USB Ein-/Ausgangsmodule 46 Siemens Building Technologies Fire Safety & Security Products 08.2007 11.3 Moduladresse zuweisen 11.3.1 Module m
Herausgegeben von Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.sbt.siemens.com © 2007 Copyr
Fire Safety & Security ProductsSiemens Building Technologies SISTORE MX NVS Application Software for Network-Based Video Recording Installatio
Sicherheit 5 Siemens Building Technologies Fire Safety & Security Products 08.2007 1 Sicherheit 1.1 Zielgruppen Die Anweisungen in diesem
Liefermöglichkeiten und technische Änderungen vorbehalten. Data and design subject to change without notice. / Supply subject to availability. © 2007
51 Siemens Building Technologies Fire Safety & Security Products 08.2007 Contents 1 Safety ...
Safety 52 Siemens Building Technologies Fire Safety & Security Products 08.2007 10 Setup ...
Safety 53 Siemens Building Technologies Fire Safety & Security Products 08.2007 1 Safety 1.1 Target readers The instructions in this docume
Safety 54 Siemens Building Technologies Fire Safety & Security Products 08.2007 1.2.3 Storage Damage due to improper storage – Always stor
Scope of Delivery 55 Siemens Building Technologies Fire Safety & Security Products 08.2007 2 Scope of Delivery z USB dongle for software l
System requirements 56 Siemens Building Technologies Fire Safety & Security Products 08.2007 4 System requirements z Pentium IV 2,6 GHz or
Software components 57 Siemens Building Technologies Fire Safety & Security Products 08.2007 5 Software components During the installation
Installation 58 Siemens Building Technologies Fire Safety & Security Products 08.2007 6 Installation 6.1 Installing SISTORE MX NVS Prerequi
Installation 59 Siemens Building Technologies Fire Safety & Security Products 08.2007 5. Click Next. Î The following dialog box will appea
Sicherheit 6 Siemens Building Technologies Fire Safety & Security Products 08.2007 1.2.3 Aufbewahrung Produktschaden durch falsche Lagerung
Installation 60 Siemens Building Technologies Fire Safety & Security Products 08.2007 10. Enter the name of the program folder and click N
Installation 61 Siemens Building Technologies Fire Safety & Security Products 08.2007 14. Click Finish. Î The computer will be restarted.
Installation 62 Siemens Building Technologies Fire Safety & Security Products 08.2007 6.2 Subsequently installing a hardware driver Prereq
Installation 63 Siemens Building Technologies Fire Safety & Security Products 08.2007 Hardware driver Function CKA4810 / CKA4820 Activat
Installation 64 Siemens Building Technologies Fire Safety & Security Products 08.2007 6.3 Installing RemoteView on a client PC Prerequisit
Installation 65 Siemens Building Technologies Fire Safety & Security Products 08.2007 5. Click Next. Î The following dialog box will appea
Installation 66 Siemens Building Technologies Fire Safety & Security Products 08.2007 Î The following dialog box will appear: Abb. 5 "
Installation 67 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 6 "InstallShield Wizard Complete" dia
Installation 68 Siemens Building Technologies Fire Safety & Security Products 08.2007 6.4 Removing SISTORE MX NVS 1. Start SISTORE_MX_NVS
Configuration 69 Siemens Building Technologies Fire Safety & Security Products 08.2007 7 Configuration 7.1 Starting the software 1. Double
Lieferumfang 7 Siemens Building Technologies Fire Safety & Security Products 08.2007 2 Lieferumfang z USB-Dongle für die Softwarelizenz m
Configuration 70 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.2 Login 1. Choose Login from the File menu. 2. C
Configuration 71 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.4 Change password There are two options for changi
Configuration 72 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.5 Select language 1. Select Configuration in the
Configuration 73 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.6 Changing the language version in Windows XP 1.
Configuration 74 Siemens Building Technologies Fire Safety & Security Products 08.2007 Î The following dialog box will appear: 6. Click on
Configuration 75 Siemens Building Technologies Fire Safety & Security Products 08.2007 Î The Regional und Language Options dialog appears:
Configuration 76 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.7 Setting time and date format 1. After selectin
Configuration 77 Siemens Building Technologies Fire Safety & Security Products 08.2007 7. Select the Date tab. Î The following dialog box
Configuration 78 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.8 Resolution and file format The files stored by
Configuration 79 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.9 Set date and time of client PC Adjust the time
Systemvoraussetzungen 8 Siemens Building Technologies Fire Safety & Security Products 08.2007 4 Systemvoraussetzungen z Pentium IV mindest
Configuration 80 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.10 Get time of Client PC from an NTP Server An NT
Configuration 81 Siemens Building Technologies Fire Safety & Security Products 08.2007 7.11 Further information For more information on the
Software update 82 Siemens Building Technologies Fire Safety & Security Products 08.2007 8 Software update Should it be necessary to reinst
Setup 83 Siemens Building Technologies Fire Safety & Security Products 08.2007 10 Setup 10.1 Examples of system configurations 10.1.1 SIST
Setup 84 Siemens Building Technologies Fire Safety & Security Products 08.2007 SISTORE MX NVS supports the following network cameras: Areco
Setup 85 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.2 SISTORE MX NVS - IP camera - CKA4810/20 Abb. 12 SIST
Setup 86 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.3 SISTORE MX NVS - SISTORE RemoteView - CKA4810 / CKA4820
Setup 87 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.4 SISTORE MX NVS – SISTORE MX NVS RemoteView – multiserv
Setup 88 Siemens Building Technologies Fire Safety & Security Products 08.2007 10.5 SISTORE MX NVS - MX Multi Channel Box RCI 0601 and ATM
USB input/output modules 89 Siemens Building Technologies Fire Safety & Security Products 08.2007 11 USB input/output modules USB input/ou
Softwarekomponenten 9 Siemens Building Technologies Fire Safety & Security Products 08.2007 5 Softwarekomponenten Bei der Installation des
USB input/output modules 90 Siemens Building Technologies Fire Safety & Security Products 08.2007 11.1 Technical data of the USB input/outp
USB input/output modules 91 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 16 USB input module 1 Module add
USB input/output modules 92 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 18 USB output module 1 Relay ou
USB input/output modules 93 Siemens Building Technologies Fire Safety & Security Products 08.2007 Abb. 20 USB input and output module 1, 2
USB input/output modules 94 Siemens Building Technologies Fire Safety & Security Products 08.2007 11.3 Module addressing 11.3.1 Modules with