Siemens T1000 Manuel de service Page 115

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 132
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 114
Chapter 5 Replacing Field-Replaceable Units 5-23
b. Issue the poweron command.
c. Switch to the system console to view the POST output.
Watch the POST output for possible fault messages. The following output is a
sign that POST did not detect any faults:
Note Depending on the configuration of ALOM CMT POST variables and
whether POST detected faults or not, the system might boot, or the system might
remain at the ok prompt. If the system is at the ok prompt, type boot.
d. Return the virtual keyswitch to normal mode.
e. Issue the Solaris OS fmadm faulty command.
No memory or DIMM faults should be displayed.
If faults are reported, refer to the diagnostics flow chart in
FIGURE 3-1 for an
approach to diagnose the fault.
sc> poweron
sc> console
.
.
.
0:0>POST Passed all devices.
0:0>
0:0>DEMON: (Diagnostics Engineering MONitor)
0:0>Select one of the following functions
0:0>POST:Return to OBP.
0:0>INFO:
0:0>POST Passed all devices.
0:0>Master set ACK for vbsc runpost command and spin...
sc> setkeyswitch normal
# fmadm faulty
Vue de la page 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 131 132

Commentaires sur ces manuels

Pas de commentaire