Page 62 SITRANS LR 300 – INSTRUCTION MANUAL 7ML19985CL02
mmmmm
Parameters
Display and Reading Parameters (P060 to P063)
P060 Decimal Position (F = 2)
Defines the maximum number of decimal places used on the LCD.
In RUN mode, the decimal position is adjusted to prevent the number of digits from
exceeding the display capabilities. To keep the decimal place from shifting, reduce the
number of decimal places to that shown at 100%.
For example, if 100% = 15m, use two decimal places for readings of 15.00 or parts thereof
(e.g. 12.25).
P062 Offset Reading (F = 0.0000)
Adds the specified value to the reading displayed, usually to reference the reading to sea
level or to another datum level.
The operation of the device is not affected by the Offset Reading. This value is used for
display only. All control measurements are still referenced to empty.
P063 Minimum Reading (F = 0.0000)
Adjusts the minimum reading the product will show. This is useful on conical or parabolic
tanks to prevent negative values on the display.
P063 is only applied after P062 Offset Reading and then only if reading displays level/
volume (P001=1).
The milliAmp output is not affected.
Values (Level
measurement only)
0 no digits after the decimal point
1 1 digit after the decimal point
2 2 digits after the decimal point
3 3 digits after the decimal point
Values (Level
measurement only)
Range: -999 to 99999
Pre-set: 0.0000
Values (Level
measurement only)
Range: -999 to 99999
Pre-set: 0.0000
SITRANS LR 300.book Page 62 Monday, June 10, 2002 7:18 PM