TC35i AT Command Set
14.8 AT^SPBS
s
m
obil
e
TC35i_ATC_V02.07 Page 360 of 439 1/30/04
Confidential / Released
Parameter Description
1 To make a step forward in the alphabetically sorted phonebook.
2 To make a step backward in the alphabetically sorted phonebook.
1...maxindex The index in the sorted list of phonebook entries that identifies the first entry in
alphabetical order of names displayed.
The value of
<index-a> is determined by the value of the internal counter and
by parameter
<value>.
After a write command has terminated successfully with "OK", the value from
parameter
<index-a> is saved and retained as the new internal counter
value.
Mind after the last record of phonebook, the first entry follows.
1...maxindex The index in the sorted list of phonebook entries that identifies the second entry
in alphabetical order of names displayed.
Mind after the last record of phonebook, the first entry follows.
1...maxindex The index in the sorted list of phonebook entries that identifies the third entry
in alphabetical order of names displayed.
Mind after the last record of phonebook, the first entry follows.
string type phone number in format specified by
<type>.
the number parameter may be an empty string.
type of address octet
145 dialling string
<number> includes international access code character '+'
209 dialling string
<number> contains printable non-alphabetic non-digit charac-
ters saved with the number string.
For phonebook entries with this <type>, dialling from phonebook with
ATD><mem><n> is not possible. For further detail, check the parameter
descriptions for at command
AT+CPBW.
129 otherwise
Text assigned to the phone number.
0
(&F)
...maxindex This Parameter is only an internal parameter and cannot modified directly.
The internal counter will be reset to index 0 after a call to
ATZ or AT&F.
<value>
(num)
<index-a>
(num)
<index-b>
(num)
<index-c>
(num)
<number>
(str)
<type>
(num)
<text>
(str)(+CSCS)
<internal-counter>
(num)