TC35i AT Command Set
2. Configuration Commands
s
m
obil
e
TC35i_ATC_V02.07 Page 28 of 439 1/30/04
Confidential / Released
2. Configuration Commands
The AT Commands described in this chapter allow the external application to determine the TC35i's behaviour
under various conditions.
2.1 AT&F Set all current parameters to manufacturer defaults
Syntax
Command Description
TA sets all current parameters to the manufacturer defined profile.
Parameter Description
[0] set all TA parameters to manufacturer defaults
Notes
List of parameters reset to manufacturer default can be found in Chapter Factory Default Settings
Restorable with AT&F
.
In addition to the default profile, you can store an individual one with
AT&W. To alternate between the two pro-
files enter either
ATZ (loads user profile) or AT&F (restores factory profile).
Every ongoing or incoming call will be terminated.
Exec Command
AT&F[<value>]
Response(s)
OK
PIN ASC0 MUX1 MUX2 MUX3
! % % % %
Reference(s)
V.25ter
<value>
(num)