2 NC Machine Data 01.93
2.3 Spindle-specific values (max. 2 spindles) (Softkey SPINDLE DATA)
2.3 Spindle-specific values (max. 2 spindles)
(Softkey SPINDLE DATA)
MD
No.
Standard
value
400* Spindle assignment 810/820T:
1300H
810/820M
:
0H
2300H
1)
2300H
1)
---
---
401* Drift compensation (spindle) 0 +/- 500 --- VELO
402* Zero mark shift spindle 0 16383 --- 360° /(MD 4590x4)
403* Max. speed for gear 1
2)
500 16000 --- rev/min
404* - // - gear 2
2)
1000 16000 --- rev/min
405* - // - gear 3
2)
2000 16000 --- rev/min
406* - // - gear 4
2)
4000 16000 --- rev/min
407* - // - gear 5
2)
4000 16000 --- rev/min
408* - // - gear 6
2)
4000 16000 --- rev/min
409* - // - gear 7
2)
4000 16000 --- rev/min
410* - // - gear 8
2)
4000 16000 --- rev/min
411* Min. speed for gear 1 50 16000 --- rev/min
412* - // - gear 2 500 16000 --- rev/min
413* - // - gear 3 1000 16000
--- rev/min
414* - // - gear 4 2000 16000 --- rev/min
415* - // - gear 5 2000 16000 --- rev/min
416* - // - gear 6 2000 16000
--- rev/min
417* - // - gear 7 2000 16000 --- rev/min
418* - // - gear 8 2000 16000 --- rev/min
Description
Input
unit
Ref.
system
Maximum
input value
1) When using the SPC measuring circuit module
2) Max. speeds for the various gears must be specified in ascending order.
Max. speed
spindle speed for DAC = 10 volts
2-8 © Siemens AG 1990 All Rights Reserved 6ZB5 410-0DM02
SINUMERIK 810 GA3/820 GA3 (IA)
Alarm 6027
Aaaa