RUGGEDCOM ROS
User Guide
Chapter 3
Device Management
Configuring an Ethernet Port 63
Figure 25: Port Parameters Table
2. Select an Ethernet port. The Port Parameters form appears.
7
11
6
5
4
3
2
1
8
12
9
10
Figure 26: Port Parameters Form
1. Port Box 2. Name Box 3. Media Box 4. State Box 5. AutoN Box 6. Speed Box 7. Dupx Box 8. FlowCtrl Box 9. LFI
Box 10. Alarm Box 11. Apply Button 12. Reload Button
3. Configure the following parameter(s) as required:
Parameter Description
Port Synopsis: 1 to maximum port number
Default: 1
The port number as seen on the front plate silkscreen of the switch.
Name Synopsis: Any 15 characters
Default: Port x
A descriptive name that may be used to identify the device connected on that port.