RUGGEDCOM ROS
User Guide
Chapter 5
Setup and Configuration
Configuring LLDP for an Ethernet Port 181
Section 5.8.3
Configuring LLDP for an Ethernet Port
To configure LLDP for a specific Ethernet Port, do the following:
1. Navigate to Network Discovery » Link Layer Discovery Protocol » Configure Port LLDP Parameters.
The Port LLDP Parameters table appears.
Figure 137: Port LLDP Parameters Table
2. Select a port. The Port LLDP Parameters form appears.
54
3
2
1
Figure 138: Port LLDP Parameters Form
1. Port Box 2. Admin Status List 3. Notifications Options 4. Apply Button 5. Reload Button
3. Configure the following parameter(s) as required:
Parameter Description
Port Synopsis: 1 to maximum port number
Default: 1
The port number as seen on the front plate silkscreen of the switch.
Admin Status Synopsis: { rxTx, txOnly, rxOnly, Disabled }
Default: rxTx
rxTx: the local LLDP agent can both transmit and receive LLDP frames through the port.
txOnly: the local LLDP agent can only transmit LLDP frames.