RUGGEDCOM ROS
User Guide
Chapter 4
System Administration
Configuring an Alarm 105
Figure 67: Latched Alarms Table
To clear the passive alarms from the list, do the following:
1. Navigate to Diagnostics » Clear Latched Alarms. The Clear Latched Alarms form appears.
1
Figure 68: Clear Latched Alarms Form
1. Confirm Button
2. Click Confirm.
Section 4.4.3
Configuring an Alarm
While all alarms are pre-configured on the device, some alarms can be modified to suit the application. This
includes enabling/disabling certain features and changing the refresh time.
To configuring an alarm, do the following:
IMPORTANT!
Critical and Alert level alarms are not configurable and cannot be disabled.
1. Navigate to Diagnostic » Configure Alarms. The Alarms table appears.