Siemens MC35 Spécifications Page 81

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 256
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 80
AT Command Set
MC35_ATC_01_V05.00 Page 81 of 256 15.07.2002
4.11.1 Wake up the ME from SLEEP mode
A wake-up event is any event that switches off the SLEEP mode and causes the ME to return to full
functionality. In short, it takes the ME back to AT+CFUN=1.
Definitions of the state transitions described in Table 7:
Yes = ME exits SLEEP mode.
No = ME does not exit SLEEP mode.
Table 7: Wake-up events in NON-CYCLIC and CYCLIC SLEEP mode
Event From SLEEP mode
AT+CFUN=0 to
AT+CFUN=1
From SLEEP mode
AT+CFUN=5 or 6 to
AT+CFUN=1
Ignition line No No
/RTS0 (falling edge) Yes No
Unsolicited Result Code (URC) Yes Yes
Incoming voice or data call Yes Yes
Any AT command
(incl. outgoing voice or data call, outgo-
ing SMS)
Not possible
(UART disabled)
No
Incoming SMS depending on mode se-
lected by AT+CNMI:
AT+CNMI=0,0 (= default, no indication
upon receipt of SMS)
AT+CNMI=1,1 (= displays URC upon
receipt of SMS)
No
Yes
No
Yes
GPRS data transfer Not possible
(UART disabled)
No
RTC alarm Yes Yes
AT+CFUN=1 Not possible
(UART disabled)
Yes
Recommendation:
· In NON-CYCLIC SLEEP mode, you can set an RTC alarm to wake up the ME and return to full
functionality. This is a useful approach because, in this mode, the AT interface is not accessible.
Vue de la page 80