8.3 AT^MONP Monitor neighbour cells
Test command
AT^MONP=?
Response
^MONP: (list of supported < period >s) OK
Write command
AT^MONP=[<period>]
This command can be used to retrieve information of up to six neighbour
cells automatically every n seconds. It is cancelled by any character sent
to the serial port except if autobauding is enabled (+IPR=0). Then type
character ´a´ to abort.
Response
See execute command
Parameter
<period> 1 – 254 Display period in seconds
Execute command
AT^MONP
This command can be used to obtain information of up to six neighbour
cells on request.
Response (Example)
Parameter:
Chann ARFCN (Absolute Frequency Channel Number) of the BCCH
carrier
rs RSSI value 0 – 63 (RSSI = Received signal strength indication)
dBm Receiving level in dBm
PLMN PLMN ID code
BCC Base Station colour code
C1 coefficient for base station selection
C2 coefficient for base station reselection
Reference
Siemens
Note
· Cell information can be issued in the form of unsolicited result codes
(related to <period>), or it can be queried directly using the Execute
command AT^MONI. In the first case, the ME activates its RING line
(Logic “1”) for one second to send the URC to the connected applica-
tion. In the second case, the RING line does not change.
· Due to the fact that not all necessary information of the neighbour cells
can be decoded during a connection, there are several constraints to
be considered:
- Only neighbour cells that have already been visible in IDLE mode
will be further updated, as long as they are still included in the list.
- Though new neighbour cells can be added to the list (e.g. due to
handover), their C1 and C2 parameters cannot be displayed until
the connection is released. In this case “-“ is presented for C1 and
C2.