01.93 2 NC Machine Data
2.1 General values (Softkey GENERAL DATA)
2 NC Machine Data
2.1 General values (Softkey GENERAL DATA)
1) MD 9 active after NC-Start
2) MD 20 Note max. memory extension!
Min. ring buffer variable is 1 KByte.
1 Speed behind pre-limit switch 500 15000 IS 1000 units/min
2
3 Corner deceleration rate 500 15000 IS 1000 units/min
4
5 No. of input buffer parameters 250 250
----
6 Threshold for CRC insert blocks 0 2000 IS units
7 Circle end position monitoring 5 32000
---- units
8 Max. no. of part programs 50 500 ----
9 Error window for repositioning on
the circle contour
1)
200 32000 IS units
10 Feed after block search 1000 15000 IS 1000 units/min
11 Password 0 9999
---- BCD
13 No. of tool parameters 10 10 ----
14 Cycle MD
from R parameter no.
10000 10000 ----
15 Cycle MD
to R parameter no.
10000 10000 ----
16 Cycle SD
from R parameter no.
10000 10000 ----
17 Cycle SD
to R parameter no.
10000 10000 ----
20 Variable of the ring buffer
2)
0 64 ---- KByte
100 Feedrate override position 2 1 150 --- %
101 - // - position 3 2 150 --- %
102 - // - position 4 4 150 --- %
103 - // - position 5 6 150
--- %
104 - // - position 6 8 150 --- %
Reference
system
Input
unit
Standard
value
Maximum
input value
MD
No.
Description
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0DM02 2-1
SINUMERIK 810 GA3/820 GA3 (IA)
Alarm 6027
Aaaa