Siemens High Speed Counter and Encoder Module SIMATIC 505 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Siemens High Speed Counter and Encoder Module SIMATIC 505. Siemens High Speed Counter and Encoder Module SIMATIC 505 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - High Speed Counter

SIMATIC 505High Speed Counterand Encoder ModuleUser ManualOrder Number: PPX:505–8113–2Manual Assembly Number: 2586546–0019Second Edition

Page 2 - Copyright

1-4Series 505 High Speed Counter and Encoder Module User’s Manual1.2 InputsThe HSC module has two independent channels. Each channel has fouri

Page 3 - Contents

Overview1-5Series 505 High Speed Counter and Encoder Module User’s Manual1.3 Outputs Each channel has two open collector outputs capable of driving T

Page 4

1-6Series 505 High Speed Counter and Encoder Module User’s Manual1.4 LED Indicators Each channel contains four LED indicators which provide a

Page 5 - of Figur

Overview1-7Series 505 High Speed Counter and Encoder Module User’s Manual1.5 Counting Modes 1.5.1Pulse CounterEach channel has two inputs, A and B. I

Page 6

Overview1-8Series 505 High Speed Counter and Encoder Module User’s ManualCounting Modes (continued)1.5.2Quadrature ModeFor quadrature mode, each chann

Page 7 - Overview

Overview1-9Series 505 High Speed Counter and Encoder Module User’s Manual1.5.42X QuadratureIf input A leads input B, the module counts up on both the

Page 8 - 1.1 Features

Overview1-10Series 505 High Speed Counter and Encoder Module User’s ManualCounting Modes (continued)1.5.54X Quadrature If input A leads input B, the m

Page 9

Installation2-1Series 505 High Speed Counter and Encoder Module User’s ManualChapter 2Installation2.1 Before Installing the Module 2–2. . . . . . . .

Page 10 - 1.2 Inputs

2-2InstallationSeries 505 High Speed Counter and Encoder Module User’s Manual2.1 Before Installing the Module2.1.1Visual InspectionIf there is any vis

Page 11 - 1.3 Outputs

Installation2-3Series 505 High Speed Counter and Encoder Module User’s Manual2.1.4General WiringThe count, inhibit, and unfiltered reset inputs are h

Page 12 - 1.4 LED Indicators

01/21/92Copyright 1992 by Siemens Industrial Automation, Inc. All Rights Reserved — Printed in USAReproduction, transmission or use of this document o

Page 13 - 1.5 Counting Modes

2-4InstallationSeries 505 High Speed Counter and Encoder Module User’s ManualBefore Installing the Module (continued)2.1.5Hierarchy ofFigure 2-1 provi

Page 14 - Counting Modes (continued)

Installation2-5Series 505 High Speed Counter and Encoder Module User’s Manual2.2 Selecting Counter Operation2.2.1Selecting The HSC module has two cha

Page 15 - 505 High Speed Counter

2-6InstallationSeries 505 High Speed Counter and Encoder Module User’s ManualSelecting Counter Operation (continued)2.2.2Selecting theSome application

Page 16

Installation2-7Series 505 High Speed Counter and Encoder Module User’s Manual2.3 Inserting the Module in the I/O BaseThe HSC is a single-wide module.

Page 17 - Installation

2-8InstallationSeries 505 High Speed Counter and Encoder Module User’s Manual2.4 Wiring the Module2.4.1Wiring the Wiring the module consists of wiring

Page 18 - and Encoder Module User

Installation2-9Series 505 High Speed Counter and Encoder Module User’s ManualCh1 A+Ch1 B+Ch1 RST+Ch1 INH+5–24 VDCCh2 A+Ch2 B+Ch2 RST+Ch2 INH+5–24 VDC

Page 19

2-10InstallationSeries 505 High Speed Counter and Encoder Module User’s Manual2.5 Logging the Module into the Controller2.5.1Updating the I/OAfter ins

Page 20

Installation2-11Series 505 High Speed Counter and Encoder Module User’s Manual2.5.3Viewing the I/O Use SHOW to view the I/O Configuration Chart. If t

Page 21

Programming3-1Series 505 High Speed Counter and Encoder Module User’s ManualChapter 3Programming3.1 Controller Input Words 3-2. . . . . . . . . . . .

Page 22

Programming3-2Series 505 High Speed Counter and Encoder Module User’s Manual3.1 Controller Input WordsThe HSC module is configured as three word inpu

Page 23

Contents iiiContentsChapter 1Overview1.1 Features 1-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 24 - 2.4 Wiring the Module

Programming3-3Series 505 High Speed Counter and Encoder Module User’s ManualInhibit Status. Each channel has an Inhibit Status bit in the status word

Page 25

Programming3-4Series 505 High Speed Counter and Encoder Module User’s ManualController Input Words (continued)Reset Command. Both channels have a Res

Page 26

Troubleshooting4-1Series 505 High Speed Counter and Encoder Module User’s ManualChapter 4TroubleshootingRe-seat boardCheck jumper positionand conditi

Page 27

4-2TroubleshootingSeries 505 High Speed Counter and Encoder Module User’s Manual4.1 Checking the Operation of the ModuleTo check the operation of the

Page 28 - Programming

Applications 5-1Series 505 High Speed Counter and Encoder Module User’s ManualChapter 5Applications5.1 Sprayer Example 5-2. . . . . . . . . . . . . .

Page 29 - 3.1 Controller Input Words

Applications5-2Series 505 High Speed Counter and Encoder Module User’s Manual5.1 Sprayer Example5.1.1Description A reversible DC motor drives a paint

Page 30

Applications5-3Series 505 High Speed Counter and Encoder Module User’s Manual5.1.2Solution Connect encoder signals A and B to inputs A and B of the H

Page 31

Applications5-4Series 505 High Speed Counter and Encoder Module User’s ManualSprayer Example (continued)LDC1A:N=WY40BITS1A:N=WY44BITS2A:N=WY42C12C1MOV

Page 32 - Troubleshooting

Applications5-5Series 505 High Speed Counter and Encoder Module User’s Manual5.2 Flow Rate Example5.2.1Description A flow meter outputs 200 pulses pe

Page 33

Applications5-6Series 505 High Speed Counter and Encoder Module User’s Manual5.3 Tank Filling Example5.3.1Description The HSC module measures the volu

Page 34 - Applications

iv ContentsChapter 4Troubleshooting4.1 Checking the Operation of the Module 4-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 5Appl

Page 35 - 5.1 Sprayer Example

Applications5-7Series 505 High Speed Counter and Encoder Module User’s ManualC141BITC1A: WY4N = 5C140X128C140C140 C256C140 IS USED TO INITIATE/TERMIN

Page 36

Applications5-8Series 505 High Speed Counter and Encoder Module User’s ManualTank Filling Example (continued)C51C8C51C8: AFTER 90,000 PULSES, SUBTRACT

Page 37 - Sprayer Example (continued)

Terminal Block WorksheetA-1Series 505 High Speed Counter and Encoder Module User’s ManualAppendix ATerminal Block Worksheet

Page 38 - 5.2 Flow Rate Example

SpecificationsB-1Series 505 High Speed Counter and Encoder Module User’s ManualAppendix BSpecificationsB.1 Environmental Specifications B-2. . . . .

Page 39 - 5.3 Tank Filling Example

SpecificationsB-2Series 505 High Speed Counter and Encoder Module User’s ManualB.1 Environmental SpecificationsTable B-1Environmental SpecificationsOp

Page 40

SpecificationsB-3Series 505 High Speed Counter and Encoder Module User’s ManualB.2 Electrical SpecificationsTable B-2Electrical SpecificationsCount I

Page 41 - Logic for T

SpecificationsB-4Series 505 High Speed Counter and Encoder Module User’s ManualElectrical Specifications (continued)Count inputs are constant cu

Page 42 - Block W

SpecificationsB-5Series 505 High Speed Counter and Encoder Module User’s ManualOutputsUser voltage: 28 VDC max.. . . . . . . . . . . . . . . . . . .

Page 43 - Specifications

SpecificationsB-6Series 505 High Speed Counter and Encoder Module User’s ManualB.3 Additional CompliancesIn addition, the system complies with applica

Page 44

Customer RegistrationWe would like to know what you think about our user manuals so that we can serve you better.How would you rate the quality of our

Page 45 - B.2 Electrical Specifications

Contents vList of Figures1-1 High Speed Counter Module 1-3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 Output 1-5.

Page 46

BUSINESS REPLY MAILFIRST CLASSPERMIT NO.3JOHNSON CITY, TNFOLDFOLDPOSTAGE WILL BE PAID BY ADDRESSEENO POSTAGENECESSARYIF MAILEDIN THEUNITED STATESSIEME

Page 47

Index-1IndexAAssistance, 2-2CConfigurationselecting, 2-10updating, 2-10Configuringjumpers, 2-5User Options, 2-10Count input, 1-4Count rate, 1-2Counte

Page 48 - B.3 Additional Compliances

Index-2 QQuadrature Mode, quadruple count, 1-10Quadrature modedouble-count, 1-9single-count, 1-8Quadruple count, quadrature mode, 1-10RReferences, 2-2

Page 49 - Registration

SIMATIC is a registered trademark of Siemens AG.Series 505 and TISOFT are trademarks of Siemens Industrial Automation, Inc.Texas Instruments and TI ar

Page 50 - JOHNSON CITY

vi ContentsList of Tables1-1 Determining Count in Pulse Counter Mode 1-7. . . . . . . . . . . . . . . . . . . . . . . . . B-1 Environmental Specificat

Page 51

Overview1-1Series 505 High Speed Counter and Encoder Module User’s ManualChapter 1Overview1.1 Features 1-2. . . . . . . . . . . . . . . . . . . . . .

Page 52

1-2Series 505 High Speed Counter and Encoder Module User’s Manual1.1 FeaturesThe Series 505 High Speed Counter (HSC) module (PPX:505-7002)pro

Page 53

Overview1-3Series 505 High Speed Counter and Encoder Module User’s ManualBasePlaneConnectorPrintedCircuitBoardFront BezelBezel ScrewLEDsTerminalBlock

Commentaires sur ces manuels