GINA V4.0 System Administrator Guide – September 2000 67
Configuration language
Druck vom 24. 01.2001 17:00.31 torb-kon
This statement acts as a wildcard so that a GINA-SESSION between a T-ORB application
without the flag RESERVE and a T-ORB application with the flag RESERVE can be defined
(see SESSION). A T-ORB application can then be generated from this session in the event
of a revision generation. The normal syntax of this statement must then be used. OsId and
LayerId may not then be changed.
Customizing statements (ADMIN, CYCLICTIME, EVENTCONTROL, MAX, RMXA, START and
START_RM) are permitted after the TA_APPLICATION description of a server.
Example TA_APPLICATION ( "OS1", 1, 1, "OS1" )
{
...
}