Vue de la page 228
SITRANS P measuring instruments for pressure
Fittings - Accessories
Pressure surge reducers
2/229
Siemens FI 01 · 2009
2
Overview
The pressure surge reducer protects the pressure gage against
damage, premature wear and tear and inaccurate/fluctuating in-
dications.
Application
The pressure reducer is used when pulsations occur in the mea-
sured medium (e.g. in slow-running vapor engines, piston
pumps and compressors), or if drastic fluctuations are likely to
occur in the measured medium (e.g. in hydraulic presses and
tensile testing machines).
Design
Enclosure made of brass or stainless steel
Adjustable nozzle
Sleeve for connection to the measuring instrument
Pin for connection to supply lead
Dimensional drawings
Pressure surge reducer, dimensions in mm
Selection and Ordering data Order No.
Pressure surge reducer
Weight approx. 0,21 kg
Material Full-scale value Weight approx.
in kg
Brass 250 bar 0.21 M56340-A54
Stainless
steel
600 bar 0.21 M56340-A59
*®
