Time and date setting
83
Building Technologies
Fire Safety & Security Products
Daylight Saving Sunday Start
P27E 1E
(Value 0-5, 0= DLS Disabled)
On which Sunday in the month the daylight saving should start. Per default this is
set to the 1 Sunday in the Month.
Daylight Saving Sunday Stop
P27E 2E
(Value 0-5, 0= DLS Disabled)
On which Sunday in the month the daylight saving should end. Per default this is
set to the 3 Sunday in the Month.
Daylight Saving Month Start
P28E 1E
(Value 1-12)
On which Month in the Year the daylight saving should start. Per default this is set
to the 10 Month in the Year.
Daylight Saving Month End
P28E 2E
(Value 1-12)
On which Month in the Year the daylight saving should stop. Per default this is set
to the 3 Month in the Year.
Daylight Saving Hour Start
P29E 1E
(Value 0-23)
On which hour on the Sunday the daylight saving should start. Per default this is
set to 2, which equals to 2 o clock in the morning.
Daylight Saving Hour End
P29E 2E
(Value 0-23)
On which hour on the Sunday the daylight saving should stop. Per default this is
set to 2, which equals to 2 o clock in the morning.