Technical data
Power supply: 8-24 V AC, 10-35 V DC
Power consumption: 75 mA.
Maximum load over
the relay contacts:
2 A 28 V DC
Dimensions
(HxWxD) mm:
140x80x40
Suitable height: 1200-1400 mm from
ground to bottom edge
.
If needed, complete the installation with
ush mounting kit BB3.
Enter duress code
This is how to activate the alarm output when
forced to open the door under threat:
Enter the usual entrance code, only add 1 to the
last digit in the code.
Example 1: If the entrance code is 1234, enter
1235 instead.
Example 2: If the code is 1239, enter 1230 in-
stead.
When a duress code is entered, the door will open
at the same time as the duress output is activated.
It will remain activated until reset by somebody
entering programming mode.