Siemens SIMATIC FS600 Instructions d'exploitation Page 29

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 51
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 28
Distributed Use of SIMATIC FS600 Laser Scanner in
Category 3 / SIL 2
Entry ID: 21330889
A&D Safety Integrated Page 29/51 AS-FE-I-010-V20-EN
Copyright © Siemens AG 2007 All rights reserved
21330889_as_fe_i_010_v20_en_lscanner.doc
4.5 Important hardware component settings
The STEP 7 project delivered with this safety functional example contains
the hardware configuration and the sample code.
Below, several important settings from the hardware configuration of
STEP 7 are shown to give you an overview. It is basically possible to
change these settings (e.g. due to individual requirements), but please
consider the following note:
NOTICE
The settings shown below contribute to meeting the requirements
of category 3 / PL d / SIL 2. Changes at the settings may cause loss
of the safety function.
If you make changes to the hardware configuration of STEP 7 (e.g. add an
additional module), the sample code of the delivered STEP 7 project must
be adapted accordingly.
Overview picture
The PROFIBUS address at IM 151 HF is set using DIP switches.