Siemens RUGGEDCOM RSG2200 Guide de l'utilisateur Page 95

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 170
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 94
RUGGEDCOM ROS
User Guide
Chapter 4
System Administration
Configuring an Alarm 83
Figure 46: Latched Alarms Table
To clear the passive alarms from the list, do the following:
1. Navigate to Diagnostics » Clear Latched Alarms. The Clear Latched Alarms form appears.
1
Figure 47: Clear Latched Alarms Form
1. Confirm Button
2. Click Confirm.
Section 4.4.3
Configuring an Alarm
While all alarms are pre-configured on the device, some alarms can be modified to suit the application. This
includes enabling/disabling certain features and changing the refresh time.
To configuring an alarm, do the following:
IMPORTANT!
Critical and Alert level alarms are not configurable and cannot be disabled.
1. Navigate to Diagnostic » Configure Alarms. The Alarms table appears.
Vue de la page 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 169 170

Commentaires sur ces manuels

Pas de commentaire