Cable Connections Between Star Groups
Updating to the Split-Star Topology
If you are updating to the split-star topology, connect the cables as follows:
PortConnects to Cluster SwitchPortCluster Switch
8X28X1
9X29X1
10X210X1
11X211X1
8Y28Y1
9Y29Y1
10Y210Y1
11Y211Y1
Updating to the Tri-Star Topology
If you are updating to the tri-star topology, connect the cables as follows:
PortConnects to Cluster SwitchPortCluster Switch
10X28X1
11X29X1
8X310X1
9X311X1
10X38X2
11X39X2
10Y28Y1
11Y29Y1
8Y310Y1
9Y311Y1
10Y38Y2
11Y39Y2
Cable Connections in a Layered Topology
Connections Between Layers Within a Switch Group
This table lists the connections between layers within a switch group:
PortPIC SlotConnect to SwitchPortPIC SlotSwitch
111X12/Y12111X11/Y11
211X12/Y12211X11/Y11
311X12/Y12311X11/Y11
Cable Connections Between Star Groups 283