Web-Based Management (WBM)
4-25
Industrial Ethernet OSM/ESM Network Management
C79000-G8976-C137-08
4.8.3 OSM/ESM Counters
Figure 4-14 shows the OSM/ESM Counters window. Using the OSM/ESM
counters, you can monitor whether and how often problems occurred during
operation (for example how often the signaling contact responded). The fault
counters are cleared when the power supply to the OSM/ESM is turned off or
when you click the Reset Counters button in the window.
Figure 4-14 OSM/ESM Counters Window
No. of Signaled Faults
This indicates how often the signaling contact of the OSM/ESM responded.
No. of Changes to RM Active State
(Only in the redundancy manager mode) This indicates how often the OSM/ESM
acting as the redundancy manager changed to the active state. This state is
adopted only when the RM has detected a break on the line of OSMs/ESMs
connected to the ring ports (port 7 and 8 of 8-port devices, port 3 and 4 of 4-port
devices). If the RM mode is disabled (DIP switch RM “off”), no value is displayed.