Configuring with Web Based Management
5.6 "Interfaces" menu
SCALANCE W770/W730 to IEEE 802.11n Web Based Management
222 Configuration Manual, 11/2014, C79000-G8976-C323-03
System > Load&Save > TFTP
If necessary, change the file name "signal_recorder_SCALANCE_W700.zip" in the
"WLANSigRec" table row. In the table row "WLANSigRec", select the "Save file" entry
from the drop-down list and click the "Set Values" button.
5. The ZIP file contains two files with the results of the recording:
A PDF file
A CSV file
Measurement results
PDF file
The PDF file contains information on the configuration of the device and detailed information
about all individual measurements. There is also a graphic representation of the curve of the
RSSI values in dBm and the data rate.
If the client changes the access point (roaming) during the measurement, this is indicated by
vertical black bars with a black square at the tip. The range > -35 dBm (blue) is the
overmodulation range, in other words the WLAN card overmodulates.