Application description
Prerequisites
Commissioning of the Control Unit CU230P-2 DP with PROFIBUS ID-No: 35934076
Version 1 Issue May 2009 13/33
Copyright © Siemens AG 2009 All rights reserved
PDF_Commissioning_of_CU230P_2_DP_with Profibus_en_V1.doc
3 Prerequisites
3.1 Hardware components
Table 3-1 Hardware components
Component Type
Order No.
[MLFB]/ordering data
No. Manufacturer
S7 control
Power supply PS307 5A 6ES7307-1EA00-0AA0 1
S7-F CPU CPU 317F-2 PN/DP 6ES7317-2FK13-0AB0 1
Memory Card MMC 8 MB 6ES7953-8LP11-0AA0 1
SIEMENS
Drive
SINAMICS G120 Control Unit CU230P-2 DP 6SL3243-0BA30-1PA0 1
SINAMICS G120 Power Module PM240 6SL3224-0BE13-7UA0 1
Operator Panel IOP
*
Intelligent Operator Panel IOP 6SL3255-0AA00-4AA0 1
SIEMENS
PROFIBUS
PROFIBUS Cable 3 m SIMATIC NET, PB FC
Standard Cable GP, 2-wire,
shielded, min. ordering
quantity: 20 m sold by the
meter
6XV1830-0EH10 1
PB connector PB FC RS 485 PLUG 180,
PB connector w. fast connect
connector
6GK1500-0FC00 2
PB connector SIMATIC DP, bus connector
for PROFIBUS up to 12
Mbit/s with tilted outgoing
cable
6ES7972-0BA41-0XA0 2
SIEMENS
Motor / Line
Motor Asynchronous motor 1LA7060-4AB10 1
Motor cable, 1.5 m Motor cable 6ES7194-1LA01-0AA0 1
SIEMENS
Line supply feeder cable Line supply feeder cable - 1 -
PG/PC
PG/PC SIMATIC Field PG M 6ES7712-1BB10-0AG2 1 SIEMENS
Note:
The functionality was tested using the specified hardware components.
Similar products can be used that deviate from the list above.
*
The Intelligent Operator Panel IOP is required in order to parameterize the drive. The STARTER
commissioning tool can also be used (refer to the software prerequisites).