05.07 DNC Plant/DNC Cell (FBDN1)
4 NC data management
© Siemens AG 2010 All Rights Reserved
Motion Control Information System DNC (FBDN) - 04/10 Edition
FBDN1/4-65
Changing link administrative data
Authorized users (administrators) are authorized to define links in configuration
mode. Authorization to configure machine data must be assigned to these users
(see also: Chapter 5 - User administration).
When you choose Edit, you can enter a drive or path for a link directly in the MCF.
When you choose "Config. dialog", you can select a drive in the file system or enter
a UNC path in the screen. This means that DNC can now access these files.
Note
Files that are made visible via a link, do not have a database reference.
DNC cannot navigate in any subdirectories of the link that may be available. Only
the files that are located directly under the link node can be accessed.