SIEMENS 5930/5935 Business Gateway
User’s Guide
Chapter 4 User Setup
User Management
SIEMENS 35
Configure the TacPlus Server
Tacplus allows access control and user authentication to be managed from a remote server.To configure the
Tacplus Server:
1. Click Configure Tacplus Server on the left navigation pane of the User Management page. This displays
the Tacplus Server Configuration page.
2. In Timeout, enter the number of seconds to between retry attempts when the Tacplus Server cannot be
reached.
3. In Retry, enter the number of times the Tacplus Server should be contacted before attempting to connect
to the secondary server.
4. In CACHE Timeout, enter the number of seconds that must pass before the user must be authenticated
again.
5. For Primary and optionally Secondary servers, provide the IP Address, Port, and Secret for accessing
the Radius Server. The Secret is used to authenticatn requests between servers.