Siemens 5935 Spécifications Page 141

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 174
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 140
XMU+ Installation and Maintenance Guide rev.07 133
If XMU+ Hardware Failures Occur
Factory Reset 2
1. Power down the XMU+. See To power dow n the XMU+
on page 108.
2. Connect the XMU+ to its power supply while holding
down the Enter key.
XMU+ displays all previously installed firmware (APP)
version numbers. A * is shown beside the current
version number.
3. Press Enter to select the current firmware (APP)
version number.
XMU+ displays a message asking if you want to
perform a Factory Reset.
4. Press the Right Arrow (YES) to reset the XMU+ to its
default factory settings.
The XMU+ erases ALL messages and ALL
configurations.
5. Download configurations and messages.
See the XMU+ QuickStart Guide for more information.
TIP...
If you do not select
YES or NO, the XMU+
will time-out after
five seconds and
display the Time/
Date.