Mounting
3-4
SIMATIC Panel PC 670 / 870 Operating Unit, Equipment Manual
Edition 07/02
3.2 Installation
3.2.1 Panel PC 670
The operating unit can be fitted in the mounting cut-out with either clamps
or screws. Screwed joints are not possible with the 12.1 touchscreen
version!
Protection class IP 65 is possible when the operating unit is secured with
clamps (in conjunction with a continuous gasket).
Protection class IP 54 is achieved with screw fixings.
The permissible mounting locations will depend on the attached computing
unit.
Operating units L1 L2 L3 L4 L5 A1 A2 S1 S2
(a) with key-based front panels:
10.4 TFT / 12.1 TFT 450 290 78 465 235 16 10 ——
15.1 TFT 450 321 51 465 279 16 17 ——
(b) with touchscreen front panels:
12.1 TFT 368 290 ———16 10 35 19
15.1 TFT 450 290 81 465 235 16 10 ——
L1
L2
112 ± 0.5
L4
L5
112 ±0.5
±156
min. 1.5 max. 6
L3 ± 1
A1±1
A2
±
1
Clamp with grub screws
Drill hole for
± 0.2
± 0.2
+1
+1
Rz 120 (in gasket area)
Gasket area
M6/ 7
Pressure points
for clamps
screw fixings
L3 ± 1112± 0.5
*)
*)
S1 ± 1 S2 ± 1
S1± 1 S1± 1
*) cut-outs only for 15 TFT
(keyboard version),
(for dimensions,
see Fig. 3-1)
Fig. 3-3 Dimensions for installation of the operating unit of Panel PC 670
Mounting location
and dimensions