Vue de la page 166
Remote mount form factor
7-5
SIMATIC Panel PC 670 Computing Unit Equipment Manual
Edition 12/01
Should it be necessary to check or modify the setting, perform the following steps:
1. Unscrew the computing unit from the installation wall.
2. Unscrew the four fastening screws on the transmitter housing (Figure 7-1).
3. Remove the transmitter housing from the computing unit (there is no need to
unplug the cables).
Transmitter
Port for interconnecting
cable
Encoder S30
Computing unit
Transmitter housing
Figure 7-4 Transmitter in opened transmitter housing
4. Check (or set) the switch setting as shown in the table below:
Table 7-1 Display type setting using encoder S30
Type Resolution S30/4 S30/3 S30/2 S30/1
12 (SVGA) 800 x 600 OFF ON ON ON
15 (XGA) 1024 x 768 OFF ON ON OFF
5. Install in reverse order.