9/100
■
Technical data
3RG78 41 light curtains for Category 2 acc. to EN 954-1
3RG78 42 light curtains and light arrays for Category 4 acc. to EN 954-1
Safety category acc. to EN,
IEC 61496-1, -2
Type 2 (testable)
in combination with an external
evaluation unit of Type 2 (SIGUARD
3RG78 47 evaluation unit)
Protective field depth
•for 30 mm resolution 150 to 2400 mm
•for 55 mm resolution
300 to 2400 mm
•for 80 mm resolution
450 to 2400 mm
Protective field width, range
0.3 to 6 m
Detection capability
(resolution)
30 mm, 55 mm or 80 mm
Response time
(from interruption of protective field until
safety outputs switch off)
The response time is dependent on
the height of the protected field
(for precise response times, see
the operating instructions)
•for 30 mm resolution
8 to 29 ms
•for 55 mm resolution
8 to 19 ms
•for 80 mm resolution
8 to 15 ms
Reactivation time
(from enabling the
protective field until safety outputs switch
on)
0.5 ms for all resolutions
(for extremely brief interruptions of
the protective field, the OSSD
output remains switched off for at
least 100 ms)
Supply voltage
DC 24 V ± 20%
(external power pack with safe
isolation from the supply and 20 ms
bridging of supply failures
Current consumption
•Transmitter 75 mA
•Receiver
75 mA (without load)
Protection class I
OSSD output
pnp output, short-circuit proof,
max. 100 mA
Pollution output and fault signalling
output
pnp output, short-circuit proof,
max. 70 mA
Diagnostics interface, receiver
RS 485
Transmitter test input
+24 V = no test,
0 V or high-resist. = test
via floating NC cont. or pnp output
(sign. for test tripping min. 20 ms)
Te st execution time
10 ms
Operating mode
Protection mode without activation
and reactivation inhibit
Synchronisation
transmitter/receiver
Optical synchronisation,
2 comm. channels selectable
Ambient temperature
•Operation 0 to +55 °C
•Storage
–25 to +75 °C
Air humidity
15 to 95 % (no condensation)
Degree of protection
IP 65
Electrical connection
M12 circular connector, 8-pin
Connecting cable
7-core, 0.25 mm
2
, shielded with
integrally extruded connector,
length 5 m or 15 m (see access.)
Dimensions
•Cross-section 17 mm × 33 mm
•Length (with/and connection area)
Protective field height + 96 mm
Safety category acc. to EN,
IEC 61 496-1, -2
Typ e 4 (self-monitoring)
Protective field depth
•for 14 and 30 mm resolution 150 to 1800 mm
•for 50 mm resolution
450 to 1800 mm
•for 90 mm resolution
750 to 3000 mm
Protective field width, range
•for 14 mm resolution 0.3 to 6 m
•for 30, 50 and 90 mm resolution
0.8 to 18 m
•for light array (18 m type)
0.8 to 18 m
•for light array (60 m type)
6.0 to 60 m
Detection capability (resolution)
14 mm, 30 mm, 50 mm, 90 mm
or whole person with 2, 3 or 4
beams
Response time
(from interruption of protective field until
safety outputs switch off)
The response time rises with
the number of beams
(for precise response times, see
the technical instructions)
•14 mm
7 to 39 ms (d-scan: 10 to 78 ms)
•30 mm
7 to 20 ms (d-scan: 10 to 39 ms)
•50 mm
17 ms (d-scan: 33 ms)
•90 mm
13 ms (d-scan: 20 ms)
•2-, 3-, 4-beam
5 ms (d-scan: 8 ms)
Reactivation time
(from enabling the protective field until
safety outputs switch on)
0.5 ms for all resolutions
(for extremely brief interruptions of
the protective field, the safety
outputs remain switched off for at
least 100 ms)
Supply voltage
DC 24 V ± 20%
(external power pack with safe
isolation from the supply and 20 ms
bridging of supply failure
Current consumption
•Transmitter 75 mA
•Receiver
180 mA (without load)
Safety outputs 2 failsafe pnp outputs with
crossover monitoring
• U
amin
= U
vers
–2.7 V, I
amax
0.3 A
•Peak current
0.4 A
•Continuous current at 35 °C
0.3 A
•Continuous current at 55 °C
0.22 A
•Max. capacitive load per output
0.3 µF (Channel 2: 0,1 µF)
Pollution output and fault signalling
output
pnp output, short-circuit proof,
max. 70 mA
Safety and diagnostic interface
RS-485, 57.6 Kbaud
Transmitter test input
Closed-circuit principle,
minimum opening time 50 ms
Operating mode
Protection mode without
reactivation inhibit
Synchronisation transmitter/receiver
Optical synchronisation,
2 comm. channels selectable
Infrared light interference suppression
2 techniques selectable
•standard
high suppression
•d-scan
extremely high suppression
(response time rises with devices
with more than 15 beams)
Ambient temperature
•Operation 0 to +55 °C
•Storage
–25 to +70 °C
Air humidity
15 to 95%
Degree of protection
IP 65
Electrical connection
Via Pg 13.5 screw terminals and
plug-in connection
Connecting cable
•Transmitter 7-core, 0.5 mm
2
(max. 1.0 mm
2
)
•Receiver
7-core, 0.5 mm
2
(max. 1.0 mm
2
)
(shielded if necessary)
Cable length
max. 100 m for 1.0 mm
2
Dimensions
•Cross-section 55 mm × 52 mm
•Length
234 to 3084 mm depending on
protective field height
Introduction
SIGUARD Safety Systems—Safety Integrated
3RG784 SIGUARD Safety Light Curtains and Light Arrays
Siemens Energy & Automation, Inc.
Industrial Controls Catalog
09_Sec (097-128).qxd 07/28/03 02:28 PM Page 9/100