Interface to the User Program in the S7-200 CPU
2-13
SIMATIC NET CP 243-2 AS-i Master
C79000-G8976-C142/02
2.4.1 Identification Register in the Analog Module
Meaning
The identification register signals the I/O module identifier to indicate the existence
of an 8AI/8AO analog module with the value specified below.
The address at which the program can access the identification register depends
on the slot in which the CP 243-2 is inserted.
For further information about the special bit memory and its structure for I/O
modules refer to /4/.
Range of Values
The identification register can be read via the special bit memory area of the
S7-200 CPU. It provides the fixed value 1FH.
Example
Assuming that the CP 243-2 is inserted directly beside the S7-200 CPU.
The content of the identification register can be read via SMB 10.