Vue de la page 113
Extended example
3.2 Expanding the program
STEP 7 Basic V10.5
114 Getting Started, 12/2009, A5E02651459-01
Procedure
To program the status light so that it indicates the operating mode of the heating chamber,
follow these steps:
1. Insert a normally open contact into the fifth network of the "Main [OB1]" organization
block.
2. Interconnect the normally open contact with the tag "chamber_ON_OFF".
3. Insert the "Output coil" instruction at the end of the rung.
4. Enter the name LED in the operand placeholder of the "Output coil" instruction and
confirm the entry with the Enter key.
5. Open the device and network editor.
Note
Network incomplete
A white cross in a red circle is displayed as icon in Network 5. The icon indicates that the
interconnection or the tag definition in this network still has to be completed.