Siemens BTC-BR Manuel Page 157

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 264
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 156
Technical Product Manual
Fault analysis and repairs 1318
3 Removing and fitting housing
Section 3: Removing and fitting housing • Edition 12/2005
TU00-1318-0200302 © Siemens VDO Trading GmbH Section 3 3–65
3.16.3 Default setting for driver 2 coupling
Fig. 3-47 Default setting for driver 2 coupling
Procedure
Open the housing cover.
Undo the screw (10) slightly.
Set a gap of 1.5 mm between the coupling lever (12) and the plastic part (11).
Tighten the screw (10).
10 Screw 12 Coupling lever
11 Plastic part
10
11
12
1,5
+0,1
Vue de la page 156
1 2 ... 152 153 154 155 156 157 158 159 160 161 162 ... 263 264

Commentaires sur ces manuels

Pas de commentaire