Siemens SIMATIC TI505 Manuel de service Page 13

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 53
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 12
10 Texas Instruments Communication Driver Manual
The 305 Series driver supports the following memory types.
Memory Type Memory Area
16-Bit Word
AC Timer/Counter Accumulator (Read Only - Model 315)
R Data Registers (Not Supported - Model 315)
Memory Type Memory Area
Byte
R Data Registers (Not Supported – Model 315)
(Read Only – Models 325 and 330)
Memory Type Memory Area
Bit
IO Input/Output, Internal Relay, Shift Register
(IO373-IO377 is Read Only - Model 315)
(IO374-IO377 is Read Only - Models 325 and 330)
T Timer Element (Read Only - all models)
C Counter Element (Read Only - all models)
TC Timer/Counter Element (Read Only - all models)
SG Stage Element
Memory addresses are in octal.
www.siemenssupply.com