Fault Diagnosis
Release 04/02
6-6
Panel PC 670 Computing Unit, Equipment Manual
6.7 Error Message Appears on the Screen/Display
Error messages
The error messages issued by the system BIOS are listed below. Refer to the
relevant program manuals in the case of error messages issued by the operating
system or programs.
Press F2 during the boot routine to call in the Setup menu (refer to Chapter 5).
Error message on screen Significance/Advice
Address conflict Plug and Play Problem
Contact your technical service department.
Combination not supported Plug and Play Problem
Contact your technical service department.
IO device IRQ conflict Plug and Play Problem
Contact your technical service department.
Invalid System Configuration
Data
Plug and Play Problem
Set the RESET CONFIGURATION.DATA option in the Advanced
Setup menu.
Contact your technical service department.
Allocation Error for ... Plug and Play Problem
Please revert the last hardware modification.
Contact your technical service department.
System battery is dead
Replace and run SETUP
Battery on the CPU module is defect or empty.
Contact your technical service department.
System CMOS checksum bad
Run SETUP
Call in SETUP, define settings and store. If this message appears
during each boot routine, contact your technical service department.
Incorrect Drive A type
Run SETUP
Check the SETUP entries for drive A.
Incorrect Drive B type
Run SETUP
Check the SETUP entries for drive B.
Diskette drive A error Fault accessing drive A
Contact your technical service department.
Diskette drive B error Fault accessing drive B.
Contact your technical service department.
Failure Fixed Disk Fault accessing the hard disk.
Check the SETUP settings
Contact your technical service department.
Keyboard error Check that the keyboard is connected correctly.
Stuck Key Check whether a key on the keyboard is jammed.
System RAM Failed at offset: Memory error
Contact your technical service department.
Shadow RAM Failed at offset: Memory error
Contact your technical service department.
Extended RAM Failed at offset: Memory error
Contact your technical service department.
Failing Bits: Memory error
Contact your technical service department.