Installation, Commissioning, Cleaning and Maintenance
Industrial Ethernet OSM/ESM
C79000-Z8976-C068-04
63
The following table shows how to mount the device on different types of walls:
Wall Mounting
Concrete wall Use four wall plugs 6 mm in diameter and 30 mm
long. (drill hole 6 mm in diameter, 45 mm deep). Use
screws 4.5 mm in diameter and 40 mm long.
Metal wall
(min. 2 mm thick)
Use screws 4 mm in diameter and at least 15 mm
long.
Sandwich type plaster wall
(min. 15 mm thick)
Use an anchoring plug with at least
4 mm diameter.
Note
The module must be secured to the wall so that the mounting can carry at least four
times the weight of the module.