P1 Panelboards • Quick reference for selection and application
10
Standard Modifications
Type P1 Panelboards
Panel Options
Enclosures
Extra gutter to sides or ends of the can
24” wide boxes
Hinged trims
Door-in-door trims
Screw to the box trims
Piano hinge trims
Painted boxes
Custom colors
Increase gauge trims and boxes (See pages 12-13)
Stainless steel trims and boxes
Type 1 enclosures (Std 16 Gage / Optional 14 or 12 Gage)
NEMA 3R/12 enclosures
NEMA 4 enclosures
Panel Modifications
Enclosures
Main Bus
Standard main bus is tin-plated aluminum. For copper main
bus, add from the table for each panel. Includes copper neutral
cross bar. For copper neutral branch lugs, see miscellaneous.
• Compression lug for MLO
1
• Contactor mains - Mount in 23” enclosure ahead of panel.
- Asco 920 through 225 amps
3
- Asco 911 through 150 amps
3
- Siemens LEN through 30 amps
3
• Branch and main breaker accessories
- Handle blocks
- Handle locks
• Feed-thru lugs
1
Cannot be used in conjunction with SPD/TVSS or subfeed
breakers. Do not add height to the panel.
Feed-thru
Lugs Amp
Rating Type
Connector
CU/AL Range
250
AL/CU
Mechanical
(1)–#6 AWG-
350 kcmil
CU
Mechanical
(1)–#6 AWG-
350 kcmil
AL/CU
Compression
(1)–#6 AWG-
350 kcmil
400
AL/CU
AWG Mechanical
(2)–#1/0 -
250 kcmil or
(1)–#2 AWG-
600 kcmil
CU (1)–1/0-600 kcmil
(2)-1/0-4/0
AL/CU
Compression
(1) 400-600 kcmil AL
(1) 400-500 kcmil CU
200% neutral
1
• Copper lugs, mechanical line and branch neutral
1
• Bus mounted SPD/TVSS
1
• Service entrance labeling
Grounding of Panelboards
Ground Bars except for brazed to box are shipped with
the panel interior factory mounted.
- Non-Insulated Equipment Ground Bar – Standard
- Copper Non-Insulated Ground Bar
- AL Insulated Equipment Ground Bar
- CU Insulated Equipment Ground Bar
- Ground Bar Brazed to Box (recommended for painted boxes)
• Shunt Trip on Main or Branch
BL
2
, BLH
2
, HBL
2
, BQD
2
, xGB
2
as branch use 1” unit space for
shunt trip.
QJ2, QJ2-H, QJH2, ED2, ED4, ED6, HED4, HED6, HHED6, FD6, FXD6, HFD6
HFXD6, JXD6, JD6, HJD6, HJXD6, HQJ2H
• Remote control switches – 480V AC max. mounted in
a 23” enclosure to be cable connected to the panel.
• Time Clocks – mounted in a 23” enclosure to be cable
connected to the panel. Tork time clock can be supplied and
mounted in panelboard cabinet.
Time Clock Information and Options
Time Clock (1- or 2-Pole, Single or Double Throw Contacts,
3-Pole Single Throw) 277V Maximum with Plain Dial
Options:
Astronomical Dial
An Omitting Device
Reserve Power or Carryover
Space and Mounting Provisions Only
NEMA 4X enclosures
Special Keyed Locks (Keys are not supplied)
Panel skirts
Gaskets between trim and box
TEY
TEU1
Cat 60
LL803
LL806
All fit Fast-Latch Front
Yale 47 (NYC)
National C413A
Beck Lock 7-pin tumbler
Southco 1 4 Fastener
Corbin 1001 FAB7
Special non-Fast-Latch
Note: Specify copper or aluminum cable.
1 Do not increase panel or enclosure size.
2
Accessories on 1” pole breakers (BL, BQD, xGB, ED) will take 1” unit space.
3
External to the panel, supplied in a separate enclosure.