Siemens HB 131. 10 B Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Fours Siemens HB 131. 10 B. TCSU/TFL IMU HANDBOOK Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 47
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002
Issue 05.00 – Page 1
SIEMENS PLC,
Sopers Lane,
POOLE, Dorset
BH17 7ER
SYSTEM/PROJECT/PRODUCT: Siemens IMU
HANDBOOK FOR THE
SIEMENS T400, ST700 AND ST800
INTEGRAL MONITORING UNIT
PREPARED: Paul Cox
FUNCTION: Software Engineer
This Document is Electronically Held and Approved in Meridian
A ‘Paper Insert’ Appendix is held in the Registry – See Page 2
ISSUE: CHANGE REF.: DATE:
01.00A 06/10/93
01.00B 29/03/94
01.00C 26/04/94
01.00D 23/09/94
01.00 24/04/95
02.00A 11/04/96
02.00B 15/08/96
02.00 ANL00311 10/12/96
03.00 ANL00760 22/08/97
04.00 TS000545 18/09/01
05.00 TS002377 09/12/04
This is an unpublished work the copyright in which vests in Siemens PLC. All rights
reserved.
The information contained herein is the property of Siemens PLC and is supplied
without liability for errors or omissions. No part may be reproduced or used, except as
authorised by contract or other written permission. The copyright and the foregoing
restriction on reproduction and use extend to all media in which this information may be
embodied.
Vue de la page 0
1 2 3 4 5 6 ... 46 47

Résumé du contenu

Page 1 - INTEGRAL MONITORING UNIT

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 1 SIEMENS PLC, Sopers Lane, POOLE, Dorset BH17 7ER SYSTEM/PROJEC

Page 2

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 10 2.6 GENERAL PURPOSE INPUTS / OUTPUTS The Integral Facilities P

Page 3 - SAFETY WARNING

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 11 3. INSTALLING THE IMU RETRO-FIT KIT Note that the normal situ

Page 4 - CONTENTS

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 12 Important: The IMU firmware PB581 issue 2 should not be used w

Page 5 - Table of Figures

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 13 3.3 CONFIGURING THE INTEGRAL FACILITIES PCB Figure 1 below sh

Page 6 - Issue 05.00 – Page 6

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 14 3.3.1 CONFIGURING THE SWITCHES AND LINKS ON THE PCB The voltag

Page 7 - 1. INTRODUCTION

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 15 Note: Due to the position of the switch on the PCB, it is ver

Page 8 - SSUE HISTORY

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 16 3.4 INSTALLING THE INTEGRAL FACILITIES PCB The Controller shou

Page 9 - 2. GENERAL DESCRIPTION

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 17 3.7 CONNECTING THE IMU When the modem (as required), battery a

Page 10 - OWER SUPPLY

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 18 TfL TCUG SMALL OUTERCASET400 PELICANBT SocketVoltage Transform

Page 11 - CONTROLLERS

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 19 3.7.1 EXTENDED SYSTEM BUS The Extended System Bus is a ribbon

Page 12 - AND ST800 CONTROLLERS

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 2 ISSUE STATE Note: Source of documents is shown under Type as

Page 13 - Safety Warning

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 20 3.7.3 RS232 CABLE (NOT UTC CONTROLLERS) TO MODEM The RS232 C

Page 14

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 21 TO GEMINI BUS PROCESSOR The RS232 connection to the GEMINI Bu

Page 15 - Battery ON

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 22 3.7.4 MODEM TELEPHONE CONNECTION (NOT UTC CONTROLLERS) The Tel

Page 16

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 23 If the battery is removed in ‘TC-8 Mode’ the crimps on the Po

Page 17 - T400 LARGE OUTERCASE

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 24 default to one sensor per phase starting with sensor/channel 1

Page 18

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 25 The diagram to the right shows the Positions of the Current Tr

Page 19 - OWER AND LOCAL I/O CABLE

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 26 4. COMMISSIONING 4.1 GENERAL Commissioning of the Integral Mon

Page 20 - CABLE (NOT UTC CONTROLLERS)

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 27 4.3 CONFIGURE THE IMU 4.3.1 CONNECT THE MAINTENANCE TERMINAL T

Page 21

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 28 (also see section 6.2 on page 35) need to be entered to initia

Page 22

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 29 4.3.6 CHECK IMU CURRENT FAULT LOG There should be no unexpecte

Page 23

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 3 SAFETY WARNING In the interests of Health and Safety, when usi

Page 24

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 30 Force the controller to cycle continuously and use the KAC or

Page 25

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 31 5. MAINTENANCE 5.1 STATUS LED’S LED’s are included on the fron

Page 26 - 4. COMMISSIONING

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 32 5.2 EFFECT OF INCORRECT SWITCH / LINK SETTINGS If the Lithium

Page 27 - ONFIGURE THE IMU

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 33 5.4 FUSES The Integral Facilities Processor is fitted with thr

Page 28

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 34 6. HANDSET COMMANDS This section describes all of the IMU’s ha

Page 29

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 35 LTS LTS : {0, 1, 2 or 255} Modem Local Loop Back Test. Use “L

Page 30 - HECK IMU FAULT LOG

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 36 6.3 INPUT / OUTPUT HANDSET COMMANDS DOP DOP {0 to 3} = {0 or

Page 31 - TATUS LED’S

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 37 6.5 LAMP MONITORING COMMANDS – MAINTENANCE KAC KAC {1-23} {0-

Page 32

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 38 6.6 LAMP MONITORING COMMANDS – CONFIGURATION Note that these I

Page 33 - ICKEL-CADMIUM BATTERY

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 39 6.8 ADDITIONAL INFORMATION ON CERTAIN HANDSET COMMANDS 6.8.1 B

Page 34 - 6. HANDSET COMMANDS

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 4 CONTENTS 1. INTRODUCTION...

Page 35 - MODE HANDSET COMMANDS

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 40 6.8.2 GREEN STATE LOCATIONS (LCP) The values used for the phas

Page 36

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 41 6.8.3 LEARN STATUS BITS (KAS AND KLS) Bit 0 AWAIT_DIM - Aspec

Page 37

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 42 6.8.4 CURRENT PROFILE STORE (LMR) The LMU keeps a ‘current pro

Page 38 - NGINEERING HANDSET COMMANDS

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 43 6.8.5 FAULT LOG COMMANDS (FLC AND FLH) The current fault log c

Page 39 - ATTERY TEST TIME (BTT)

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 44 The display format which is used for the maintenance terminal

Page 40 - REEN STATE LOCATIONS (LCP)

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 45 6.9 FAULT DISPLAY CODES AND TEXT This section contains all the

Page 41

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 46 Code 40 Outstanding fault cleared Code 41 Lamp failure - veh

Page 42 - URRENT PROFILE STORE (LMR)

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 47 Code 141 Controller max times changed Code 141 Controller ex

Page 43

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 5 4.3.4 Switch to the Controller Handset Commands ...

Page 44

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 6 Figure 8 – Status LED’s on the Integral Facilities Processor Ca

Page 45 - AULT DISPLAY CODES AND TEXT

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 7 1. INTRODUCTION 1.1 PURPOSE The purpose of this document is a g

Page 46

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 8 1.4 DEFINITIONS DoT Department of Transport IMU Integral Moni

Page 47 - Issue 05.00 – Page 47

Handbook for Siemens Integral Monitoring Unit 667/HB/22380/002 Issue 05.00 – Page 9 2. GENERAL DESCRIPTION 2.1 OVERVIEW The Integral Monitoring Uni

Commentaires sur ces manuels

Pas de commentaire