HC15 Hardware Interface Description
5.3 Storage Conditions
s
HC15_HD_v01.000 Page 40 of 67 2007-1-19
Confidential / Released
5.3 Storage Conditions
The conditions stated below are only valid for modules in their original packed state in weather protected, non-
temperature-controlled storage locations. Normal storage time under these conditions is 12 months maximum.
Table 14: Storage conditions
Type Condition Unit Reference
Air temperature: Low
High
-40
+85
°C ETS 300 019-2-1: T1.2, IEC 68-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Humidity relative: Low
High
Condens.
10
90 at 30°C
90-100 at 30°C
%---
ETS 300 019-2-1: T1.2, IEC 68-2-56 Cb
ETS 300 019-2-1: T1.2, IEC 68-2-30 Db
Air pressure: Low
High
70
106
kPa IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
Movement of surrounding air 1.0 m/s IEC TR 60271-3-1: 1K4
Water: rain, dripping, icing and
frosting
Not allowed --- ---
Radiation: Solar
Heat
1120
600
W/m
2
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
Chemically active substances Not recom-
mended
IEC TR 60271-3-1: 1C1L
Mechanically active substances Not recom-
mended
IEC TR 60271-3-1: 1S1
Vibration sinusoidal:
Displacement
Acceleration
Frequency range
1.5
5
2-9 9-200
mm
m/s
2
Hz
IEC TR 60271-3-1: 1M2
Shocks:
Shock spectrum
Duration
Acceleration
semi-sinusoidal
1
50
ms
m/s
2
IEC 68-2-27 Ea
Vue de la page 39