Starting and stopping methods
Line starting and line stopping
Line starting and line stopping (applying and removing AC line
voltage) is recommended for infrequent starting and stopping of a
drive only. When AC line voltage is applied to the drive, the motor
accelerates to the speed set by the speed adjust potentiometer.
When AC line voltage is removed, the motor coasts to a stop.
Warning
Decelerating to minimum speed, dynamic braking, or coasting
to a stop is recommended for frequent starts and stops. Do
not use any of these methods for emergency stopping. They
may not stop a drive that is malfunctioning. Removing AC line
power (both L1 and L2) is the only acceptable method for
emergency stopping.
For this reason, Minarik strongly recommends installing
an emergency stop switch on both the L1 and L2 inputs
(see connection diagrams on pages 20 & 21).
Operation