Siemens SIMATIC NET PROFIBUS Instructions d'exploitation Page 249

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 490
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 248
Testing PROFIBUS
A-9
PROFIBUS Networks SIMATIC NET
6GK1970-5CA20-0AA1 Release 2 05/2000
A.2.3 Optical Time Domain Reflectometer (OTDR)
If the attenuation measurement described above indicates that the total attenuation
of the fiber-optic link is too high, the causes and the location of the problem must
be established. In this case OTDR units are used (OTDR = Optical Time Domain
Reflectometer).
Figure A-3 Optical Time Domain Reflectometer (OTDR)
OTDRs exist for the wavelengths 850 nm and 1300 nm. This means that this
method can be used for both multimode and single-mode fiber-optic cables.