Siemens S7-200PLC Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mise en réseau Siemens S7-200PLC. Polling Data Registers from Siemens S7-200 PLC Series Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 21
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
eWON Application User Guide
AUG 049 / Rev 1.0
Polling Data Registers from
Siemens S7-200 PLC Series
Contents
This guide explains how to poll data registers from Siemens S7-200
PLC Series.
Vue de la page 0
1 2 3 4 5 6 ... 20 21

Résumé du contenu

Page 1 - Siemens S7-200 PLC Series

eWON Application User GuideAUG 049 / Rev 1.0Polling Data Registers fromSiemens S7-200 PLC SeriesContentsThis guide explains how to poll data registers

Page 2 - Table of Contents

Chapter 5.2 Step 2 - Linking the PLC with the eWON 5.2.1 IntroductionThe eWON can be connected to the PLC either using a serial connection supporti

Page 3 - 2. Hardware requirements

Chapter 5.2.3 ISOTCP Ethernet link Link the LAN interface of the eWON with the Ethernet card of the PLC and make sure that the eWON LAN IP address i

Page 4

Chapter 5.3 Step 3 - Creating tags in the eWON1. Go back to the configuration menu and select Tag Setup. If you are starting from scratch, the list

Page 5 - 4. PLC protocol compatibility

Chapter Enter a Topic Name: A, B or C. The topic must have been configured in the IO server page (see § 5.1 Step 1 - Configuring the IO Server). Type

Page 6 - 5. Implementation steps

Chapter Invalid character in tag name: check name for spaces and invalid characters.Invalid IO name for tag: check tag address syntax.Invalid topic n

Page 7

Step 4. Monitoring tagsChapter 6.6. Step 4. Monitoring tags1. Go to the View I/O page from the Main Menu to check tag values and status.2. You can ch

Page 8

Troubleshooting tags in errorChapter 7.7. Troubleshooting tags in errorA tag value displayed in red in the View IO page indicates that the quality

Page 9

Troubleshooting tags in errorChapter 7.To get more information about the nature of the error and the sequence of events before and after the error occ

Page 10 - RS422, RS485

Appendix 1 – Syntax of S7-200 tag addressesChapter 8.8. Appendix 1 – Syntax of S7-200 tag addresses 8.1 General tag address format<Memory Type>

Page 11

Appendix 1 – Syntax of S7-200 tag addressesChapter 8. 8.4 ExamplesAddress Pointing toMW4 the Word at address 4 (in bytes) in the Internal MemoryHCL1

Page 12

Table of Contents1. Objective

Page 13

Appendix 2 – PPI cablesChapter 9.9. Appendix 2 – PPI cables 9.1 Standard serial eWONYou can use a standard straight RS485 cable with the following pi

Page 14

Revision historyRevision Level Date Description1.0 22/06/12 First issueiDocument build number: 26Note concerning the warranty and the rights of owner

Page 15 - 6. Step 4. Monitoring tags

ObjectiveChapter 1.1. ObjectiveThe objective of this document is to explain how the eWON can poll data registers out of one or more PLCs.Polling PLC d

Page 16

Hardware requirementsChapter 2.The eWON features the S7200 IO Server that is dedicated to the S7-200 Series PLCs from Siemens. Since firmware 5.7,

Page 17

Software requirementsChapter 3.3. Software requirementseWON configuration software:The eWON is configured through its web server. All yo

Page 18 - 8.3 Modifiers

Implementation stepsChapter 5.5. Implementation steps 5.1 Step 1 - Configuring the IO Server1. Go to the eWON Web page either using a point-to-point

Page 19 - 8.6 Status register

Implementation stepsChapter 5.4. A. eWON with serial port (not MPI), set the Protocol Type, Baud Rate, Parity, Reply Timeout, and PPI Ad

Page 20 - 9. Appendix 2 – PPI cables

Implementation stepsChapter 5.4. B. For an eWON with MPI port, the configuration fields are slightly different. You have to select the protocol PPI

Page 21 - Document build number: 26

Implementation stepsChapter 5.7. The Global Device Address is the address of the PLC to be polled. Examples of Global Device Addresses are given in th

Commentaires sur ces manuels