Siemens 4015 Instructions d'exploitation

Naviguer en ligne ou télécharger Instructions d'exploitation pour Téléphones Siemens 4015. Siemens 4015 Operating instructions Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Safety notes
This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before installation, read
the operating instructions and observe the product-specific requirements for the installation location. Use only original spare parts for repair and
maintenance. Unauthorised opening and repair by other persons will invalidate all claims for liability, replacement or warranty services.
Technical Data
Supply voltage: 110 / 240V 50/60Hz
Operating temperature:
- 10°C to +55°C
Power consumption: < 0,1 W Storage temperature: - 10°C to +60°C
Relay output: 1 changeover contact 16A 250V~ cos ϕ = 1 Operating principle: Type 1.B. S. T. IEC/EN 60730-1,
Accuracy: ± 1 s /day at 25°C IEC/EN 60730-2-7
single-strand multi-strand Operation in a normal environment
Wire cross-sections: 1,5...4 mm
2
1,5...2,5 mm
2
Degree of contamination:
2
Program blocks: 28 adjustable Installation: in distribution panel
Battery reserve: 6 years
Operating modes: Mains power (the relay does not switch in the event of a power failure)
Battery operation, full operation without mains power.
1 2
5
4
3
1200W
100W
1400VA
1x 58W ≤ 7μF
3600W
+
c
R
1800W
+
1800W
2300W
+
1 2
5
4
3
1 2 3 4 5 6 7
0
12
24
ON
OFF
Opens menu selection.
Confirm a selection or apply the parameters
(OK).
Select the options or set the parameters.
Program overview
Day of the week
Current time
5-way switch
Relay status display
Set and enable/disable the switching times.
Flashing cursor indicates day
and time
5-way switch
7LF4 4015
GB
292350/01
251426.41.19 “02”
Vue de la page 0
1 2 3 4

Résumé du contenu

Page 1 - 7LF4 4015

Safety notesThis product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks. Before insta

Page 2 - Changing to summer time +1h

YEARSTRT Setting the timeSetting the dateChanging to summer time +1hYEARYEARMONEUUSNOSPECEUUSNOSPECYEARSTRTMON.STRTDAYSTRTMON.ENDEUUSNOSPECFreely pro

Page 3 - Altering/deleting programs

EXITTIMEDATESU-WIPROG Virtually turn the dial to select the switch-on time first, e.g. Monday 06.15Use to select the hour, in this case 6. Then use

Page 4

 Permanent switching ON/OFF Mains failureEXITTIMEDATESU WIPROGSU WIPROGTESTAUTOONPROGTESTAUTOONOFFONOFFONONOFFOFF3 Changing the batteryHardware R

Commentaires sur ces manuels

Pas de commentaire