SPPA-T1000
System Overview
Siemens CI 760 : 2006/2007
FIM Field Interface Module
DAD Debugging and Diagnostic System
SoftAS has a Central Controller (CC) architecture with
remote and/or central I/Os. It has very fast response
times, achieved through the ultra high speed processing
and data handling capabilities. The CC implements all
functions like open loop control, closed loop control
and measurements. It supports fully the automation
hierarchy (individual control level, group control level,
unit control level) of the control structure in a plant.
All the process control algorithms implemented in
the system conform to the concepts laid down for
distributed control systems.
SPPA-T1000 : Basic Con guration
Overview
SPPA-T1000 is an advanced Distributed Control
System enriched with the latest concepts and
features to ful ll the growing requirements of the
market. It has been speci cally designed for control
of all types and sizes of power plants. It is based
upon the proven features of Teleperm XP innovated
with latest technological enhancements to offer
open, universal and web-enabled platforms,
excellent availability, high operational comforts
and an extremely easy engineering process.
SPPA-T1000 comprises of the following major
constituents:
SoftAS Automation System
SoftOM Operation & Monitoring System
SoftTurbo Turbine Control System
SoftFS TMR (Triple Modular Redundant)
Control System for high safety and
high availability applications
SoftBuzz Bus System & Interfaces
GUES
+
Graphical User Engineering
System
Operation
&
Monitoring
HMI HMI ENG. HMI HMI
Central / Remote I/O / Intelligent
eld devices
ENG.
CC
Unit Control
Group Control
Sub-group / Individual control
Measurement system
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - Overview

1/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007• FIM Field Interface Module• DAD Debugging and Diagnostic SystemSoftAS has a Central Cont

Page 2 - System conformance

10/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007large extent, the pre-commissioning checks. Connection between the FIM and I/O module is throu

Page 3 - Closed Loop Control

11/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007Example 3 : It is the confi guration in which the system bus and the terminal bus are redundant

Page 4 - Open loop Control

12/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007• Obsolescence proof, seamless upgradation to future technologies• Choice of OM operating sy

Page 5 - Controller

13/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007Secure investmentsSPPA-T1000 ensures that the investments on a Distributed Control System are

Page 6 - • Burner management system

SPPA-T1000Typical system confi gurationSiemens CI 760 : 2006/2007SPPA-T1000 System Confi guration

Page 7 - • Terminal bus

2/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007Input/ Output modules mounted in I/O stations serve as the interface to the process. These I/O

Page 8

3/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007It is recommended to observe in addition the following rules and guidelines in order to provide

Page 9 - Field Interface Module ‒ FIM

4/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007The control tuning parameters e.g. the proportional gain Kp or the reset time Tn can be fed to

Page 10 - Redundancy

5/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007Predictive control Interdependencies in the process & disturbances in variables are integra

Page 11 - OM Server

6/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007is much better as compared to the conventional controllers as it reacts faster to the disturban

Page 12 - Siemens CI 760 : 2006/2007

7/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007ensure highest degrees of safety and availability.The SoftTurbo provides fl exibility to choose

Page 13

8/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007System BusThis bus is used for communication between the individual participants. The participa

Page 14 - Typical system confi guration

9/13SPPA-T1000System OverviewSiemens CI 760 : 2006/2007logics. It also integrates the entire hardware engi-neering of the I&C system. GUES+ is a

Commentaires sur ces manuels

Pas de commentaire